{"id":8854,"date":"2024-07-11T14:33:11","date_gmt":"2024-07-11T06:33:11","guid":{"rendered":"https:\/\/www.lneya.com\/?p=8854"},"modified":"2024-07-11T14:33:54","modified_gmt":"2024-07-11T06:33:54","slug":"data-center-liquid-cooling","status":"publish","type":"post","link":"https:\/\/tw.lneya.com\/es\/uncategorized\/data-center-liquid-cooling.html","title":{"rendered":"\u00bfQu\u00e9 unidad de refrigeraci\u00f3n es compatible con la refrigeraci\u00f3n l\u00edquida para centros de datos?"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">\u00bfQu\u00e9 unidad de refrigeraci\u00f3n es compatible con la refrigeraci\u00f3n l\u00edquida para centros de datos?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:16px;line-height:28px;text-indent:2em;color:#666666;background-color:#9ed2f3;padding:10px 10px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-black-color has-text-color has-link-color wp-elements-ca28b2378ea722193c5ec5de6d015136 wp-block-paragraph\" style=\"font-size:18px\">Data center liquid cooling usually matches a variety of cooling equipment to achieve efficient heat management and ensure that servers and IT equipment operate within a safe operating temperature range.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color has-link-color wp-elements-36448a1d97ca60818b0f81c44cb04f60 wp-block-paragraph\" style=\"text-transform:capitalize\"><strong>Cooling unit for data center liquid cooling:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-abc9efd4f82a328e541a268b3cc9708a wp-block-paragraph\"><strong>Cold Plates:<\/strong> directly attached to the CPU, GPU and other heat-generating components of the server, and remove heat through liquid cooling medium.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-07d379339fc465de66ba15e0130f9f11 wp-block-paragraph\"><strong>Immersion Cooling System:<\/strong> directly immerse the server in non-conductive coolant, and exchange heat through direct contact with the liquid, which is suitable for high-density computing environments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-62181c515b5904c29b97be2e4c8601b0 wp-block-paragraph\"><strong>Indirect Contact Liquid Cooling System: <\/strong>heat is exchanged with the coolant inside the server through an intermediary fluid (such as fluorinated liquid) in a heat exchanger outside the server, and then the intermediary fluid is transferred to the external cooling system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-f373583ed6a7ceeb4cfada90fa17fbcd wp-block-paragraph\"><strong>Coolant Distribution Unit (CDU):<\/strong> responsible for the circulation, filtration, pressure control and possible temperature regulation of the coolant, and is the core component of the liquid cooling system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-c1c46ffc077409443fee7aa69edf5135 wp-block-paragraph\">Heat Exchanger: used to transfer the heat in the coolant to the external cooling medium, such as water or air, including plate, tube or mixed heat exchangers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-0b05b598b41a404009c752474882bc9d wp-block-paragraph\"><strong>Cooling Tower or Dry Cooler:<\/strong> located at the end of the liquid cooling system, used to discharge the accumulated heat in the heat exchanger to the atmosphere, or complete the heat exchange through the air cooling medium in the dry cooler.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-aa53ff149670e698cca75d50ab8c909c wp-block-paragraph\"><strong>Bomba de circulaci\u00f3n:<\/strong> promotes the circulation of coolant in the system to ensure the efficiency of heat exchange.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-5bda3677849607b85b74983c10b3768a wp-block-paragraph\"><strong>Water Treatment System:<\/strong> used to treat and maintain the purity of the coolant to avoid corrosion and microbial growth.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-c27a4ddc5b15c37a910ebf979ea6b43b wp-block-paragraph\" style=\"font-size:18px\">In summary, whether it is liquid cooling or traditional air cooling system, the selection and configuration of data center cooling equipment are determined by comprehensive consideration of factors such as the scale of the data center, energy consumption requirements, regional climate conditions and business needs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"padding-top:29px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\"><div class=\"post_in_list_head modle_title2\"><h3><span style=\"font-size:31px;\" class=\"main-title\">Data Center Liquid Cooling Chiller<\/span><span style=\"color:#e21f2f;font-size:14px;\" class=\"as-title\">Cold Plate Cooling or Immersion Cooling<\/span><\/h3><div class=\"title_boout\"><div class=\"title_bo\" style=\"border-bottom:4px solid #f29900;\"><\/div><\/div><\/div>\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\"><div id=\"post_in_list2\" class=\"post_in_list_out\" style=\"margin-bottom:20px;\"><ul class=\"post_in_list row3  nobig\" data-cat=\"\"data-tag=\"cdu%ef%bc%8c-data-center-cooling\"data-nb=\"4\"data-rand=\"\"data-page=\"2\" data-modle=\"post_in_list2\"data-pbtn=\"MORE\"data-pbtnicon=\"fas fa-clipboard-list\"data-seo2=\"\"data-wtitlesize=\"16\"data-wtitlecolor=\"\"data-wtitlehight=\"55\"data-btncolor=\"#146ba2\"data-first=\"\"data-b2=\"\"data-b1=\"0\"data-row=\"3\"data-canshu=\"0\"data-wtitlecolor2=\"\"data-home=\"https:\/\/tw.lneya.com\/es\"><li  ><div class=\"case_pic\"title=\"Unidad de distribuci\u00f3n de refrigerante (CDU) \/ enfriador\">\n<a href=\"https:\/\/tw.lneya.com\/es\/uncategorized\/coolant-distribution-unit-cdu-chiller.html\">\n<figure >\n<img decoding=\"async\" class=\"lazyload\"  src=\"https:\/\/tw.lneya.com\/wp-content\/themes\/smartenterprise\/images\/loading.png\"  data-src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2023\/06\/CDU.jpg\" alt=\"Unidad de distribuci\u00f3n de refrigerante (CDU) \/ enfriador\"      \/>\n<figcaption><span>CDU will become the mainstream thermal solution in the data center. In general, cooling systems with radiators, fans, air conditioning units, etc. are considered insufficient for CPUs over 300W. To continue normal operation of the 300-1000W high-p&#8230;<\/span><\/figcaption>\n<\/figure>\n<\/a>\n<\/div><div class=\"case_text\" title=\"Unidad de distribuci\u00f3n de refrigerante (CDU) \/ enfriador\" style=\"height:55px;\"><h4 class=\"posts_titles\" >\n<a style=\"font-size:16px;\" href=\"https:\/\/tw.lneya.com\/es\/uncategorized\/coolant-distribution-unit-cdu-chiller.html\">Unidad de distribuci\u00f3n de refrigerante (CDU) \/ enfriador<\/a>\n<\/h4><p >CDU will become the mainstream thermal solution in the data center. In general, cooling systems with radiators, fans, air conditioning units, etc. are considered insufficient for CPUs over 300W. To continue normal operation of the 300-1000W high-p&#8230;<\/p><\/div><a style=\"color:#146ba2;border:1px solid#146ba2\"  href=\"https:\/\/tw.lneya.com\/es\/uncategorized\/coolant-distribution-unit-cdu-chiller.html\" class=\"btn_url\"><i class=\"fa fa-fas fa-clipboard-list\"><\/i>M\u00c1S<\/a><\/li><\/ul><div class=\"tishi\"><p class=\"loading\"><i class=\"fas fa-spinner\"><\/i>cargando...<\/p><p class=\"lasetpost\">\u5df2\u7ecf\u662f\u5230\u6700\u540e\u4e00\u7bc7\u5185\u5bb9\u4e86\uff01<\/p><\/div><\/div><\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>","protected":false},"excerpt":{"rendered":"<p>What cooling unit is compatible with data center liquid cooling? Cooling unit for data center liquid cooling: Cold Plates: directly attached to the CPU, GPU and other heat-generating components of the server, and remove heat through liquid cooling medium. Immersion Cooling System: directly immerse the server in non-conductive coolant, and exchange heat through direct contact [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":true,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[1],"tags":[227],"class_list":["post-8854","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-data-center-liquid-cooling"],"metadata":{"_edit_lock":["1720679635:1"],"themepark_post_img":[""],"themepark_post_img_re":[""],"themepark_post_img_cover":[""],"themepark_post_img_fixed":[""],"themepark_post_hide_title":["1"],"themepark_paddingblock":[""],"footnotes":[""],"_edit_last":["1"],"catce":["sidebar-widgets4"],"views":["1843"],"_wp_old_slug":["what-cooling-unit-is-compatible-with-data-center-liquid-cooling"]},"taxonomy_info":{"category":[{"value":1,"label":"\u672a\u5206\u7c7b"}],"post_tag":[{"value":227,"label":"data center liquid cooling"}]},"featured_image_src_large":false,"author_info":{"display_name":"lneyaadmindy","author_link":"https:\/\/tw.lneya.com\/es\/author\/lneyaadmindy"},"comment_info":0,"category_info":[{"term_id":1,"name":"\u672a\u5206\u7c7b","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":152,"filter":"raw","cat_ID":1,"category_count":152,"category_description":"","cat_name":"\u672a\u5206\u7c7b","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":227,"name":"data center liquid cooling","slug":"data-center-liquid-cooling","term_group":0,"term_taxonomy_id":227,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/posts\/8854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/comments?post=8854"}],"version-history":[{"count":0,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/posts\/8854\/revisions"}],"wp:attachment":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/media?parent=8854"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/categories?post=8854"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/tags?post=8854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}