{"id":9891,"date":"2024-11-13T12:57:57","date_gmt":"2024-11-13T04:57:57","guid":{"rendered":"https:\/\/www.lneya.com\/?p=9891"},"modified":"2024-11-13T13:03:19","modified_gmt":"2024-11-13T05:03:19","slug":"laboratory-polymerization-reactor-water-cooling-chiller","status":"publish","type":"post","link":"https:\/\/tw.lneya.com\/es\/uncategorized\/laboratory-polymerization-reactor-water-cooling-chiller.html","title":{"rendered":"Laboratory Polymerization Reactor Water Cooling Chiller"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-black-color has-text-color has-link-color has-medium-font-size wp-elements-7f9e8084f741e0b3512bf0b6b253b5a7\">Laboratory Polymerization Reactor Water Cooling Chiller<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<p class=\"wp-block-paragraph\">Laboratory Polymerization Reactor Water Cooling Chiller is a device used to accurately control the temperature inside the reactor, especially for polymerization reactions that need to be carried out under specific temperature conditions. This equipment provides a stable temperature environment through a water bath circulation system to ensure efficient and repeatable reactions.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"790\" height=\"803\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/MINI-CHILLER-02.png\" alt=\"\" class=\"wp-image-9882\" srcset=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/MINI-CHILLER-02.png 790w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/MINI-CHILLER-02-295x300.png 295w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/MINI-CHILLER-02-768x781.png 768w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/MINI-CHILLER-02-12x12.png 12w\" sizes=\"auto, (max-width: 790px) 100vw, 790px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-9ac00cf961d1ea846fe5a532228b76c6 wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-themecolor-1-color has-text-color has-link-color wp-elements-de200d1692302a6df135699846568200\" style=\"font-size:18px\">Main Features<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol class=\"wp-block-list\">\n<li>Amplia gama de temperaturas:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The temperature range is usually from 5\u00b0C to 95\u00b0C, which can cover the temperature requirements of most polymerization reactions.<\/li>\n\n\n\n<li>Some advanced models can provide lower or higher temperature ranges, such as -20\u00b0C to 200\u00b0C.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"2\" class=\"wp-block-list\">\n<li>High-precision temperature control:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PID controller or other advanced temperature control technology is used to achieve high-precision temperature control.<\/li>\n\n\n\n<li>The control accuracy is usually \u00b10.1\u00b0C or less, ensuring temperature stability and consistency.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"3\" class=\"wp-block-list\">\n<li>Rapid heating and cooling capabilities:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Heating: Heat the water in the water bath through an electric heater.<\/li>\n\n\n\n<li>Cooling: Cool the water in the water bath to the required temperature through a cooling water circulation system or compressor refrigeration.<\/li>\n\n\n\n<li>Rapid heating and cooling capabilities can improve experimental efficiency, especially when temperature conditions need to be changed frequently.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"4\" class=\"wp-block-list\">\n<li>Circulation pump:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Circulate the water in the water bath between the reactor and the water bath to ensure uniform temperature distribution.<\/li>\n\n\n\n<li>The flow rate of the circulation pump should match the needs of the reactor, usually between a few liters per minute and tens of liters per minute.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Safety protection measures:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Overtemperature protection: Automatically cut off the power supply when the temperature exceeds the set value.<\/li>\n\n\n\n<li>Overpressure protection: Prevent the system pressure from being too high.<\/li>\n\n\n\n<li>Leak detection: Detect whether the system has leaks.<\/li>\n\n\n\n<li>Emergency stop button: Quickly stop the system operation in an emergency.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"6\" class=\"wp-block-list\">\n<li>User interface:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Touch screen or digital display: Intuitively display the current temperature, set temperature and other parameters.<\/li>\n\n\n\n<li>User-friendly operation interface: Easy to set and monitor temperature, support programming and data logging functions<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-themecolor-1-color has-text-color has-link-color wp-elements-4f1bd7e5ecca74584f9b885177991dee\" style=\"font-size:18px\">Application Examples<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol class=\"wp-block-list\">\n<li>Polymerization:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In organic synthesis, many polymerization reactions need to be carried out under specific temperature conditions to ensure the selectivity and yield of the reaction.<\/li>\n\n\n\n<li>For example, free radical polymerization, ionic polymerization, ring-opening polymerization, etc.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"2\" class=\"wp-block-list\">\n<li>Chemical synthesis:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In other chemical reactions, such as esterification, condensation, etc., precise temperature control is also required.<\/li>\n\n\n\n<li>For example, synthesis of pharmaceutical intermediates, fine chemicals, etc.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"3\" class=\"wp-block-list\">\n<li>Material Science:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In the process of preparing polymer materials, nanomaterials, etc., precise temperature control is required to obtain the required material properties.<\/li>\n\n\n\n<li>For example, synthesis of polymer nanoparticles, preparation of composite materials, etc.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-themecolor-1-color has-text-color has-link-color wp-elements-bcc9bad98e77ba5f87417c711cc1b6c5\" style=\"font-size:18px\">Selection Points<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol class=\"wp-block-list\">\n<li>Rango de temperatura:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ensure that the equipment can cover the required temperature range (5\u00b0C to 95\u00b0C or lower to -20\u00b0C).<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"2\" class=\"wp-block-list\">\n<li>Temperature Control Accuracy:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Choose a system with high-precision temperature control, such as a PID controller, to ensure temperature stability.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"3\" class=\"wp-block-list\">\n<li>Heating and Cooling Capacity:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select heating and cooling power suitable for the reactor capacity and the required temperature change rate.<br>\u2022The heating power is usually in the range of several kilowatts, and the cooling capacity is based on the required cooling rate.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"4\" class=\"wp-block-list\">\n<li>Circulation pump flow rate:<br>\u2022Select a circulation pump flow rate suitable for the reactor capacity to ensure uniform temperature distribution.<br>\u2022The flow rate is usually between a few liters per minute and tens of liters per minute.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"5\" class=\"wp-block-list\">\n<li>Safety:<br>\u2022Ensure that the system has multiple safety protection measures, such as over-temperature protection, over-pressure protection, leak detection, etc., to ensure the safety of operators and equipment.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<ol start=\"6\" class=\"wp-block-list\">\n<li>Maintenance cost:<br>\u2022Choose a system that is easy to maintain and operate to reduce long-term operating costs.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:98%\">\n<p class=\"wp-block-paragraph\">The laboratory polymerization reactor water cooling chiller machine is a key equipment to ensure that the polymerization reaction is carried out under precise temperature conditions. By selecting the appropriate heating and cooling capacity, circulation pump flow rate, and high-precision temperature control system, precise temperature control can be achieved to improve the efficiency of the reaction and the quality of the product. It is recommended to consult a professional equipment supplier or engineer before purchasing.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:1%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"padding-top:29px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\"><div class=\"post_in_list_head modle_title2\"><h3><span style=\"font-size:31px;\" class=\"main-title\">WATER COOLNG CHILLER<\/span><\/h3><div class=\"title_boout\"><div class=\"title_bo\" style=\"border-bottom:4px solid #f29900;\"><\/div><\/div><\/div>\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\"><div id=\"post_in_list2\" class=\"post_in_list_out\" style=\"margin-bottom:20px;\"><ul class=\"post_in_list row4  nobig\" data-cat=\"\"data-tag=\"\"data-nb=\"4\"data-rand=\"\"data-page=\"2\" data-modle=\"post_in_list2\"data-pbtn=\"MORE\"data-pbtnicon=\"fas fa-clipboard-list\"data-seo2=\"\"data-wtitlesize=\"16\"data-wtitlecolor=\"\"data-wtitlehight=\"50\"data-btncolor=\"#146ba2\"data-first=\"\"data-b2=\"\"data-b1=\"0\"data-row=\"4\"data-canshu=\"0\"data-wtitlecolor2=\"\"data-home=\"https:\/\/tw.lneya.com\/es\"><\/ul><div class=\"tishi\"><p class=\"loading\"><i class=\"fas fa-spinner\"><\/i>cargando...<\/p><p class=\"lasetpost\">\u5df2\u7ecf\u662f\u5230\u6700\u540e\u4e00\u7bc7\u5185\u5bb9\u4e86\uff01<\/p><\/div><\/div><\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>","protected":false},"excerpt":{"rendered":"<p>Laboratory Polymerization Reactor Water Cooling Chiller Laboratory Polymerization Reactor Water Cooling Chiller is a device used to accurately control the temperature inside the reactor, especially for polymerization reactions that need to be carried out under specific temperature conditions. This equipment provides a stable temperature environment through a water bath circulation system to ensure efficient and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":true,"themepark_post_main_b":"#ffffff","themepark_post_main_p":100,"themepark_paddingblock":true,"footnotes":""},"categories":[1],"tags":[268,267],"class_list":["post-9891","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-reactor-chiller","tag-water-cooling-chiller"],"metadata":{"_edit_lock":["1731474201:1"],"themepark_post_img":[""],"themepark_post_img_re":[""],"themepark_post_img_cover":[""],"themepark_post_img_fixed":[""],"themepark_post_hide_title":["1"],"themepark_post_main_b":["#ffffff"],"themepark_paddingblock":["1"],"footnotes":[""],"_edit_last":["1"],"catce":["sidebar-widgets4"],"views":["1636"],"rank_math_og_content_image":["a:2:{s:5:\"check\";s:32:\"bab864c7ae271ea6b4c46e9115d527b4\";s:6:\"images\";a:1:{i:0;i:9882;}}"]},"taxonomy_info":{"category":[{"value":1,"label":"\u672a\u5206\u7c7b"}],"post_tag":[{"value":268,"label":"reactor chiller"},{"value":267,"label":"water cooling chiller"}]},"featured_image_src_large":false,"author_info":{"display_name":"lneyaadmindy","author_link":"https:\/\/tw.lneya.com\/es\/author\/lneyaadmindy"},"comment_info":0,"category_info":[{"term_id":1,"name":"\u672a\u5206\u7c7b","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":152,"filter":"raw","cat_ID":1,"category_count":152,"category_description":"","cat_name":"\u672a\u5206\u7c7b","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":268,"name":"reactor chiller","slug":"reactor-chiller","term_group":0,"term_taxonomy_id":268,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw"},{"term_id":267,"name":"water cooling chiller","slug":"water-cooling-chiller","term_group":0,"term_taxonomy_id":267,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/posts\/9891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/comments?post=9891"}],"version-history":[{"count":0,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/posts\/9891\/revisions"}],"wp:attachment":[{"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/media?parent=9891"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/categories?post=9891"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tw.lneya.com\/es\/wp-json\/wp\/v2\/tags?post=9891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}