Conoscenza della manutenzione di un refrigeratore a bassa temperatura da 12HP (8,9kW)
The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company’s product quality, improve production efficiency, but also extend the service life of the 12HP (8.9kW) low-temperature chiller by using the knowledge learned.
1. In the initial operation of the 12HP (8.9kW) low-temperature chiller, the oil level, oil return and oil cleanliness of the compressor should be observed frequently. If the oil is dirty or the oil level drops, it should be replaced or added in time to avoid poor lubrication and affect refrigeration. machine is running.
2. For air-cooled: the air-cooler should be cleaned frequently to maintain a good heat exchange state, and the condenser should be checked frequently for scaling problems, and the scale should be removed in time.
3. For water-cooled: Always check the turbidity of the cooling water, if the cooling water is too dirty, it needs to be replaced, whether the water pump is working normally, whether the valve switch is effective, whether the cooling water tower and the fan are normal.
4. For the air-cooled evaporator: it is necessary to check the defrosting situation frequently. Whether the defrosting is timely and effective will affect the cooling effect and cause the refrigeration system to return to liquid.
5. Always observe the compressor running status of the 12HP (8.9kW) low-temperature chiller, check its exhaust temperature, and pay special attention to the running status of the system when operating in a seasonal change, and adjust the liquid supply and condensing temperature of the system in time.
6. Carefully listen to the running sound of the compressor, cooling tower, water pump or condenser fan, find out and deal with it in time, and check the vibration of the compressor, exhaust pipe and water pump at the same time.
7. After 30 days of operation, the refrigerating oil and drying filter should be replaced once, and after half a year of operation (depending on the actual situation). For systems with higher cleanliness, the refrigeration oil and filter drier should be replaced after six months of operation.
Our LNEYA is a professional chiller manufacturer, our customers are located in Europe, America and Southeast Asia. For the 12HP (8.9kW) low temperature chiller, you can contact us if you have any questions.
Raccomandazioni correlate
-
Precautions for safe use of heat transfer oil temperature control equipment
1996With the extensive use of thermal oil temperature control equipment, the safe use of thermal oil temperature control equipment is a concern for users. For manufacturers, it is very important to share the precautions for the use of thermal oil temp...
Visualizza dettagli -
Analisi delle caratteristiche dei refrigeratori di precisione LNEYA
2020Oggi, in molte produzioni industriali, i refrigeratori industriali sono necessari per raggiungere lo scopo della refrigerazione nelle operazioni di produzione. Ciò dimostra che i refrigeratori svolgono un ruolo molto importante in varie produzioni industriali. Il refrigeratore di precisione utilizza ...
Visualizza dettagli -
Quali sono i requisiti di installazione dei refrigeratori per litografia?
2173In order to ensure the reliable and normal operation of the chiller of the lithography machine and prevent the failure of the chiller caused by improper water distribution pipeline construction, the following matters should be paid attention to wh...
Visualizza dettagli -
Applicazione del TCU nei sistemi di circolazione per la refrigerazione e il riscaldamento
2270Nel processo di sintesi farmaceutica e nelle operazioni di chimica fine, spesso si verificano forti reazioni esotermiche, come la reazione di ossidazione e la neutralizzazione acido-base. Per queste reazioni fortemente esotermiche, se il controllo è improprio o se...
Visualizza dettagli
工業冷水機製造商 LNEYA Taiwan