Quali sono gli effetti di un'interruzione di corrente sulla cella frigorifera ad azoto liquido?
Different industries have different temperature requirements for cryogenic cryostats. Of course, there are many types of cryogenic cryostats. The refrigeration methods used in different industries are different. LNEYA uses compressor refrigeration to achieve refrigeration. The effect is similar to or better than liquid nitrogen cryogenic cryostat.
However, there are still customers who use liquid nitrogen cryogenic cryostats, and customers who encounter power failures when they encounter them do not know how to solve them.
One is the frequent power outage. If the power is cut off frequently, then there will be some damage in the next time the liquid nitrogen cryogenic cold box is started. The compressor is out of the working state, then the compressor will be on the compressor. There is damage. If the power outage is not used for a long time, it is also easy to cause the pipeline inside the liquid nitrogen cryogenic cold box to be damaged and the pipeline refrigerant to leak. Obviously, the impact is relatively large and prone to failure.
In two cases, it is not energized for a long time, because it is cold in the northern part of the winter, so many customers cut off the electricity of the liquid nitrogen cryogenic low temperature box. So what can you do in the end? If the refrigerant is not energized for a long time, the refrigerant will be converted from a gaseous state to a liquid state during operation, and it will be very easy to cause damage to the pipeline, which will lead to leakage. That is, leaking refrigerant.
Then don’t frequent power outages. If there is no power failure when the compressor is not working, if there is a sudden power failure and then the power is turned on immediately when the compressor is working, the chance is caused by the large pressure difference between the two ends of the compressor. The liquid nitrogen cryogenic cold box has no way to work, so the thermal protection is stopped. If the protection zone of the liquid nitrogen cryogenic cold box is damaged, the motor will be burnt if it is serious.
It seems that this situation is also more complicated. If you feel that the liquid nitrogen is cold and cold, you can choose LNEYA cryogenic low temperature box or ultra low temperature freezer, and the cooling effect is good.
Raccomandazioni correlate
-
Volare per sogno, creare maggiore gloria, la cerimonia annuale di [Wuxi Guanya LNEYA] si è conclusa con successo
2572Inadvertently 2019 has passed This year Thanks to everyone for the trust and support of Guanya LNEYA Eye-catching glory From every step of the solid Thank you all the way Dream-seeking career 2020 Let us continue to work together for a win-win sit...
Visualizza dettagli -
Low-temperature coolant circulation pump used with rotary evaporator
2361The chemical and pharmaceutical fields are the largest end consumer markets for cryogenic coolant circulation pumps. With the increasing demand for low-temperature coolant circulation pumps in this market, the application of cryogenic pumps in the...
Visualizza dettagli -
Uscita di refrigerazione del circolatore di raffreddamento a bassa temperatura
1728La potenza frigorifera del circolatore di raffreddamento a bassa temperatura varia a seconda delle condizioni di lavoro. Pertanto, quando si effettua il calcolo del processo all'inizio, è necessario tenere conto della potenza frigorifera del circolatore...
Visualizza dettagli -
Come rendere i refrigeratori a bassissima temperatura più efficienti dal punto di vista energetico
1576Nei tempi moderni, la protezione dell'ambiente e il risparmio energetico sono il tema dello sviluppo, così come il refrigeratore industriale. Allora, come migliorare il vostro refrigeratore industriale per ottenere una maggiore conservazione dell'energia? Innanzitutto, per prevenire e ridurre le incrostazioni di ult...
Visualizza dettagli