Hybrid car battery test equipment cooling capacity description
Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehicle battery test equipment, once the outer surface of the insulation layer is found to have wet or frosted parts, it means that the thickness of the insulation material is insufficient or has been damp, and the insulation material should be added or replaced in time.
When the equipment is installed, a layer of insulation cotton is placed on the evaporator and the pipeline to prevent loss of cooling capacity. If the hybrid vehicle battery test equipment is slow in cooling, first check whether the thickness of the pipe insulation layer is not enough, or if the insulation layer is damaged, be sure to pack the insulation cotton and ensure that the thickness is sufficient!
Check for air in the equipment cooling system. When installing the hybrid vehicle battery test equipment, whether it is inside the unit, water pump, or pipeline, there can be no air, even if there is only a little air, the cold hybrid vehicle battery test equipment can not operate normally. In addition, there is a film inside the pump, and you must remember to tear it off before installation. Otherwise, the circulating water has no way to circulate or the circulation is very slow, which directly affects the operation of the hybrid vehicle battery test equipment.
Check the moving parts of the refrigeration compressor of the hybrid vehicle battery test equipment for wear, or increase the clearance, resulting in a decrease in the volume of gas. The compressor is the heart of the cooling water machine. If there is a problem with the compressor, the hybrid vehicle battery test equipment will not work. Therefore, the periodic inspection and maintenance of the compressor cannot be ignored.
The poor efficiency of equipment refrigeration compressors is also one of the reasons. In the long-term operation of the hybrid vehicle battery test equipment, the wear of the moving parts, the increase of the matching clearance or the tight sealing will reduce the actual air volume of the compressor and reduce the cooling capacity. Check the refrigeration compressor. If the repair is not good, it should be replaced in time. Air in the system can also cause this to happen. At this time, the exhaust pressure and temperature increase, the power consumption increases, and the cooling capacity decreases.
The cooling of the hybrid vehicle battery test equipment is related to the data of the hybrid vehicle battery test process, so the cooling capacity needs to be better according to the requirements.
Raccomandazioni correlate
-
Soluzione per la risoluzione dei problemi dei piccoli refrigeratori sigillati da tavolo
1846Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
Visualizza dettagli -
Quali sono i componenti che migliorano le prestazioni dei refrigeratori industriali?
2331I refrigeratori industriali sono attrezzature indispensabili nella produzione di LNEYA. Con il suo normale funzionamento, avremo una migliore efficienza lavorativa e una maggiore qualità del prodotto. Il sistema di refrigerazione di un refrigeratore industriale è composto principalmente da quattro...
Visualizza dettagli -
16. - 18. Giugno 2020 | L'Expo dei test automobilistici in Europa-LNEYA
346L'Automotive Testing Expo Europe è una fiera per il collaudo, la valutazione e l'ingegneria della qualità nel settore automobilistico. È uno degli eventi più importanti del suo genere in Europa. La fiera presenta le tecnologie e i servizi più recenti per migliorare la qualità, la sicurezza...
Visualizza dettagli -
Descrizione del principio di funzionamento della camera di prova d'urto ad alta e bassa temperatura
2097Spot high and low temperature impact test chamber, also known as three-box high and low temperature impact test chamber, high and low temperature impact test chamber is mainly composed of low temperature storage chamber, high temperature storage c...
Visualizza dettagli
工業冷水機製造商 LNEYA Taiwan