Soluzioni per i guasti degli accessori dell'apparecchiatura di controllo automatico della temperatura del laser a semiconduttore
Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulating water pipe is too small, and the diameter of the circulating water pipe is increased to ensure the normal water circulation.
Semiconductor laser automatic temperature control icing in the circulating water tank may be set too low to correct the set value; there may be no circulating water in the water tank, short circuit water circulation between the chilled water outlet and the inlet; may be the temperature control table out of control Replace the temperature control table with high-voltage faults, poor heat dissipation, the radiator is too dirty, the cleaning radiator can be bad, improve the ventilation conditions, the cooling fan does not work, check whether the fan motor burns out, short-circuit repair or replace the motor; high-pressure engine damage, replacement of high voltage Bad; poor cooling, insufficient refrigerant or pipeline leakage, replenishing refrigerant or repairing after leak detection, vacuuming and replenishing refrigerant, poor heat dissipation, radiator is too dirty, the radiator valve is not opened or opened too small, the radiator is cleaned, Open the valve fully.
Semiconductor laser automatic temperature control pump failure may be semiconductor laser automatic temperature control pump motor coil short, open circuit, repair motor coil or replace the motor, if the pump overload protector automatically jumps, the current limit of the protector is within the allowable range Press the reset button halfway as appropriate.
Semiconductor laser automatic temperature control temperature according to the table temperature display digital up and down jump may be the temperature control table damage, repair or replace the temperature control table, may be poor temperature line contact, repair or replace the temperature line, may be the temperature line and temperature measurement The body is dirty and the temperature measuring body is wiped clean.
The semiconductor laser automatic temperature control compressor failure may be that the compressor coil is short, open circuit, replace the matching compressor, the compressor overload protector automatically trips, and the current limit of the protector is appropriately adjusted and pressed within the allowable range. Reset button.
In order to avoid some faults in the accessories of the semiconductor laser automatic temperature control, it is recommended to maintain a lot of instructions on the automatic temperature control of the semiconductor laser and do the maintenance work.
Raccomandazioni correlate
-
Analysis of Advantages and Disadvantages of Screw Water Chiller
2382Compared with other types of chillers, the overall energy consumption of high-quality screw water chiller is relatively small. Because the production technology of screw water chiller is more advanced and less energy is used, the equipment can qui...
Visualizza dettagli -
Dove verrà utilizzato il reattore? E il sistema di controllo della temperatura del reattore?
1699Generally, non professionals should be confused about the reactor. The reactor is composed of reactor body, reactor cover, jacket, agitator, transmission device, shaft seal device, support, etc. It is generally understood as a container with physi...
Visualizza dettagli -
Prestare attenzione all'installazione del circolatore di raffreddamento ad alta e bassa temperatura.
2464I circolatori di raffreddamento ad alta e bassa temperatura possono funzionare meglio solo se sono installati correttamente. Se l'installazione non è stata eseguita a regola d'arte durante il processo di installazione, i circolatori di raffreddamento ad alta e bassa temperatura...
Visualizza dettagli -
Tre guasti comuni dei refrigeratori a vite raffreddati ad aria
2664Errore di comunicazione: il controllore del computer controlla vari moduli tramite linee di telecomunicazione e scheda di interfaccia totale, quindi la causa principale dell'errore di comunicazione è lo scarso contatto o la rottura delle linee di comunicazione, in particolare l'interfaccia...
Visualizza dettagli
工業冷水機製造商 LNEYA Taiwan