Quali sono gli interventi di manutenzione dei refrigeratori a glicole nel funzionamento quotidiano?
Nel funzionamento quotidiano del refrigeratore di glicole, se non viene effettuata la manutenzione, l'effetto di raffreddamento sarà ridotto. Pertanto, per migliorare l'efficienza operativa, si consiglia di eseguire la necessaria manutenzione quotidiana. Refrigeratore...

Refrigeration system inspection: Generally, after long-term use of ethylene glycol chillers, various problems will inevitably occur. In the event of a failure, the use of each part of the machine should be carefully checked, focusing on the refrigeration system, electrical system, air system and water system to determine whether their functions are normal. We usually examine them by sound and appearance. If there is a problem, it is recommended to replace it in time.
Refrigerant inspection: Regularly check whether the refrigerant of the glycol chiller leaks: It can be determined by referring to the parameters displayed by the high and low pressure meter on the front panel of the main unit. According to the temperature change of the air temperature (winter and summer), the pressure display of the glycol chiller is also different. When the low temperature chiller is working normally, the high pressure shows 11-17kg, and the low pressure shows 3-5kg.
Cooling water system inspection: It is normal to check whether the cooling water system of the ethylene glycol chiller is normal, whether the cooling water tower fan and water spray shaft are in good operation, and whether the water supply in the built-in water tank of the chiller is normal.
System cleaning: Glycol chillers should be cleaned annually after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good cooling effect.
Voltage and current inspection: Regularly check whether the voltage and current of the glycol chiller are stable and whether the compressor is running normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
The above aspects are some of the areas that require routine maintenance. Of course, there are many other details that need your attention.
Raccomandazioni correlate
-
Operation method of reaction kettle for circulating heating device
2049The laboratory single-layer glass reactor equipped with the circulating heating device can place a flask containing the reaction solvent on the inner layer for stirring reaction, and the interlayer can realize constant temperature heating and cons...
Visualizza dettagli -
Precauzioni per l'utilizzo del refrigeratore a ricircolo LNEYA
2091Il refrigeratore a ricircolo a bassa temperatura di LNEYA può essere utilizzato con strumenti di supporto (come evaporatori rotanti, vasche di fermentazione, reattori chimici, apparecchiature di liofilizzazione, reattori biofarmaceutici, ecc.
Visualizza dettagli -
Importanza dei refrigeranti nei sistemi di prova delle batterie dei veicoli a nuova energia
2397If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of...
Visualizza dettagli -
Mechanical cold assembly equipment is dedicated to cold processing assembly of metal parts
1796Mechanical cold assembly equipment is a method of processing workpieces at temperatures below -130℃. Cryogenic treatment can significantly improve the toughness of the workpiece without reducing the strength and hardness of the workpiece. Mechanic...
Visualizza dettagli
工業冷水機製造商 LNEYA Taiwan