How to judge the operating status of the chemical and pharmaceutical constant temperature control sy
Nowadays, many pharmaceutical and chemical industries use LNEYA’s constant temperature control system. How to judge its operation status during operation?
There should be no noise in the cylinder of the chemical and pharmaceutical thermostatic control system, only the normal and regular sound of the inhalation valve. The condenser cooling water should be sufficient, the water pressure should be above 0.12MPA, and the water temperature should not be too high. There should be no foot heating and frosting on the cylinder wall, and the surface temperature difference should not exceed 15-20 degrees. For refrigerated or low-temperature systems, frosting on the suction pipe can generally reach the suction port; for high-temperature conditions, the suction pipe should not be condensed Frost, condensation is normal.
Chemical and pharmaceutical constant temperature control system Crankcase oil temperature small constant temperature control system does not exceed 70 degrees and not less than 10 degrees. The lubricating oil may have foam, and the exhaust temperature should not be too high. Too high and close to the flash point of domestic refrigeration oil will be detrimental to the equipment. The condensing pressure is not easy to be too high, and the construction capacity of the condensing pressure cold storage is affected by the water source, condensing method and refrigerant. The oil level of the crankcase shall not be lower than 1/2 of the horizontal centerline of the sight glass.

Chemical and pharmaceutical thermostatic control system. The hand-touched horizontal accumulator and oil separator should be cool in the upper part and lower part, and the liquid or oil level at the junction of cold and hot. The safety valve or bypass valve should be cool at the low pressure end, otherwise the high and low pressure series gas. During operation, the evaporating pressure and the suction pressure should be similar, and the exhaust pressure and condensing pressure should be similar to the accumulator pressure.
There should be a temperature difference between the cooling water in and out of the chemical and pharmaceutical constant temperature control system. If there is no or very slight temperature difference, it means that the heat exchanger is dirty and needs to be cleaned. The system should be sealed, and no refrigerant or lubricating oil should be leaked. The shaft seal of the fluorine small constant temperature control system should not drip oil. The temperature of the shaft seal and bearing of the constant temperature control system for chemical and pharmaceutical industries does not exceed 70 degrees. The valve body of the expansion valve is evenly frosted or condensed, but there should be no thick frosting at the inlet. When the fluid passes through the expansion valve, only a dull, small sound can be heard. The pointers of the pressure gauges in the system should be relatively stable and the temperature indication should be correct.
The above conditions related to the chemical and pharmaceutical thermostatic control system can be used to judge the operation status. It is recommended that the operator observe more to determine the faulty sound in time and solve it effectively.
Raccomandazioni correlate
-
Come scegliere e abbinare i refrigeratori?
2061In fact, a die is a heat exchanger. Heat is transferred from melted plastic to the die, and then from the die to the circulating cooling medium - ice water. Only a small part of the heat is transferred into the air and the pressure template of the...
Visualizza dettagli -
You Must Not Know the Low Temp Freezer Technology
2314For freezer, everyone knows they are used to store things. However, for this operation, we do not necessarily know that I will popularize the ultra low temp freezer today. The temperature of the ultra low temp freezer can reach minus 60 degrees Ce...
Visualizza dettagli -
Il punto di ingresso per la selezione dei refrigeratori industriali
2101I refrigeratori industriali sono dispositivi di refrigerazione che assemblano frigoriferi, condensatori, evaporatori, valvole di espansione, sistemi di controllo e quadri elettrici su una base o un telaio comune. In base al metodo di reiezione del calore, l'unità può essere suddivisa...
Visualizza dettagli -
Unità di controllo della temperatura del reattore TCU con anello di controllo PID
2173L'unità di controllo della temperatura del bollitore di reazione LNEYA adotta il circuito di controllo PID, che trova applicazione in molti campi. L'unità di controllo della temperatura del bollitore di reazione tcu del circuito di controllo PID adotta un sistema di refrigerazione a ciclo completamente chiuso, con...
Visualizza dettagli
工業冷水機製造商 LNEYA Taiwan