Introduzione alla preparazione del funzionamento del refrigeratore a bassa temperatura
Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.
Before running the refrigeratore a bassa temperatura, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.
Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.
Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%–100%, then 100%–0%, then manually stop the oil pump.
Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 –55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.
With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.
Raccomandazioni correlate
-
Prima di avviare i refrigeratori industriali, è necessario eseguire i seguenti lavori
19512. For the compressor unit with water system, carefully check whether the cooling water system and chilled water system have water, and whether the water pressure is normal, whether the pipeline system of cooling water and chilled water is unblock...
Visualizza dettagli -
How To Reduce Operating Costs For Electric Vehicle Power Battery Testing Equipment?
1997Since many harsh environments easily affect the operating power of electric vehicle power battery testing equipment, in order to ensure the safety of equipment operation, enterprises need to choose a suitable safety environment when installing ele...
Visualizza dettagli -
Istruzioni per il test dei componenti delle società di ispezione dei trucioli
1982Con il continuo sviluppo dell'industria del collaudo dei componenti, sono nate aziende di collaudo dei chip e anche LNEYA ha introdotto apparecchiature per il collaudo dei chip. Il vettore di test della società di controllo dei chip è...
Visualizza dettagli -
Descrizione del programma del sistema di apparecchiature per il test dei chip di memoria
2186Con il rapido sviluppo dell'industria dei componenti, anche le apparecchiature di test dei chip di memoria hanno fatto grandi progressi. Ma quanto ne sanno gli utenti delle apparecchiature di test dei chip di memoria? Al fine di semplificare le fasi di test, ridurre la complessità del...
Visualizza dettagli