{"id":2492,"date":"2024-03-19T10:48:43","date_gmt":"2024-03-19T02:48:43","guid":{"rendered":"https:\/\/www.lneya.com\/news\/system-of-water-cooled-chillers.html"},"modified":"2024-03-19T10:48:44","modified_gmt":"2024-03-19T02:48:44","slug":"system-of-water-cooled-chillers","status":"publish","type":"post","link":"https:\/\/tw.lneya.com\/it\/news\/system-of-water-cooled-chillers.html","title":{"rendered":"How to maintain the lubrication system of water-cooled chillers"},"content":{"rendered":"<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">Medium-sized water cooled chiller,<br \/>\nrefrigeration temperature range from -80 <\/span>\u2103<span lang=\"EN-US\">~ -30<\/span>\u2103<span lang=\"EN-US\">, safe,<br \/>\nreliable, rapid cooling for the liquid, widely used in petrochemical, medical,<br \/>\npharmaceutical, biochemical and freeze-dried, military and other high-tech industries.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<img decoding=\"async\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2023\/05\/21583742497.jpg\" alt=\"\"><\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">When the water cooled chiller is below 80<\/span>\u2103<span lang=\"EN-US\"> ~ 30<\/span>\u2103<span lang=\"EN-US\"> below zero<br \/>\nin the running system, people pay more attention to refrigerator, frozen water<br \/>\ncycle system and electric control system, so the lubrication system is often<br \/>\noverlooked. However, this system is also very important to the water cooled<br \/>\nchiller. The maintenance of the water cooled chiller is indispensable, now we<br \/>\nare going to tell you something about it.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">1. Observe the normal oil surface, oil<br \/>\ntemperature and oil pressure in the daily inspection.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">2. Regularly check the oil quality<br \/>\naccording to the oil change index stipulated in the frozen lubricating oil, and<br \/>\nreplace or supplement the filtered new oil.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">3. Pay attention to check and adjust the<br \/>\nend face clearance of the oil pump in the middle and overhaul, and replace the<br \/>\npump when necessary. The end face clearance of the pump varies from 0.03 to<br \/>\n0.08mm. Please refer to the assembly technical requirements and factory<br \/>\nregulations of the pump for concrete value.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">4. Regularly replace or clean the filter<br \/>\ncore, pipeline, and crankcase.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">The maintenance of the lubrication system<br \/>\nof the water cooled chiller requires techniques, which mainly involves the<br \/>\nperformance of the compressor&#8217;s main engine. It is recommended to be operated<br \/>\nby professionals to avoid unnecessary losses.<\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\"><\/p>\n<p>\u00a0<\/p>\n<p><\/span>\n<\/p>\n<p class=\"MsoNormal\">\n\t<span lang=\"EN-US\">If you are purchasing our LNEYA<br \/>\nwater-cooled chiller, you can contact our after-sales team. If you have<br \/>\npurchase needs or questions in this regard, you can also contact our team<br \/>\nsales@lneya.com, we will reply to you as soon as possible.<a name=\"_GoBack\"><\/a><\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Medium-sized water cooled chiller, refrigeration temperature range from -80 \u2103~ -30\u2103, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries. \u00a0 When the water cooled chiller is below 80\u2103 ~ 30\u2103 below zero in the running system, people pay more attention to refrigerator, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[44],"tags":[],"class_list":["post-2492","post","type-post","status-publish","format-standard","hentry","category-news"],"metadata":{"views":["1887"],"_wp_old_date":["2023-05-16"],"_edit_last":["1"],"rank_math_og_content_image":["a:2:{s:5:\"check\";s:32:\"995d054844de81e4fab1511ac199aaac\";s:6:\"images\";a:1:{i:0;i:2493;}}"]},"taxonomy_info":{"category":[{"value":44,"label":"NEWS"}]},"featured_image_src_large":false,"author_info":{"display_name":"lneyaadmindy","author_link":"https:\/\/tw.lneya.com\/it\/author\/lneyaadmindy"},"comment_info":0,"category_info":[{"term_id":44,"name":"NEWS","slug":"news","term_group":0,"term_taxonomy_id":44,"taxonomy":"category","description":"","parent":0,"count":803,"filter":"raw","cat_ID":44,"category_count":803,"category_description":"","cat_name":"NEWS","category_nicename":"news","category_parent":0}],"tag_info":false,"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/posts\/2492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/comments?post=2492"}],"version-history":[{"count":0,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/posts\/2492\/revisions"}],"wp:attachment":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/media?parent=2492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/categories?post=2492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/tags?post=2492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}