{"id":6825,"date":"2024-02-22T14:38:27","date_gmt":"2024-02-22T06:38:27","guid":{"rendered":"https:\/\/www.lneya.com\/?p=6825"},"modified":"2024-11-21T13:09:34","modified_gmt":"2024-11-21T05:09:34","slug":"flt-chillers","status":"publish","type":"post","link":"https:\/\/tw.lneya.com\/it\/uncategorized\/flt-chillers.html","title":{"rendered":"FLTZ -45\u2103~90\u2103"},"content":{"rendered":"<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"padding-bottom:14px;padding-top:28px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-themepark-block-themepark-product-head content_pro bing undefined\" style=\"background-color:#ffffff;margin-bottom:20px;\"><div class=\"tab_pic\" style=\"width:47%\"><div class=\"left_post_pic\"><a class=\"swipebox\" href=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/chiller2.jpg\"><img decoding=\"async\" class=\"lazy lazyload\" data-src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/chiller2.jpg\" src=\"https:\/\/tw.lneya.com\/wp-content\/themes\/smartenterprise\/images\/loading.png\" alt=\"FLTZ -45\u2103~90\u2103\"\/><\/a><\/div><\/div><div class=\"ds\" style=\"width:48%\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><header class=\"post_title_head\" ><div class=\"title\"><h1 class=\"h1title\" style=\"font-size:24px;color:#146ba2;\">Semiconductor Cooling Chiller<\/h1><span class=\"stitle\" style=\"color:#e21f2f;font-size:20px;\">FLTZ  -45\u2103~90\u2103<span><\/div><div class=\"description\"><span ><i class=\"fa fa-folder\"><\/i><a  href=\"https:\/\/tw.lneya.com\/it\/uncategorized\">\u672a\u5206\u7c7b<\/a> <\/span><\/div><\/header><ul class=\"csbox_pt\"  ><li style=\"border-bottom:1px solid #ececec;\"><span style=\"color:#666666;width:165px;\">Precisione della temperatura<\/span><span style=\"color:#146ba2;\">\u00b10.1\u2103<\/span><\/li><li style=\"border-bottom:1px solid #ececec;\"><span style=\"color:#666666;width:165px;\">Controllo del flusso<\/span><span style=\"color:#146ba2;\">25~75\/min 6bar max<\/span><\/li><li style=\"border-bottom:1px solid #ececec;\"><span style=\"color:#666666;width:165px;\">Refrigent<\/span><span style=\"color:#146ba2;\">R404A<\/span><\/li><li style=\"border-bottom:1px solid #ececec;\"><span style=\"color:#666666;width:165px;\"> Gamma di potenza<\/span><span style=\"color:#146ba2;\">380V 3,5kW~16kW<\/span><\/li><\/ul><div class=\"tagbox\"><a target=\"_blank\" id=\"tagss\" href=\"https:\/\/tw.lneya.com\/it\/tag\/cooling-chiller\">refrigeratore di raffreddamento<\/a><a target=\"_blank\" id=\"tagss\" href=\"https:\/\/tw.lneya.com\/it\/tag\/semiconductor-chiller\">refrigeratore per semiconduttori<\/a><\/div>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size has-normal-font-size\"><a class=\"wp-block-button__link has-monte-white-color has-themecolor-1-background-color has-text-color has-background wp-element-button\" href=\"mailto:market@lneya\" style=\"border-radius:10px\" target=\"_blank\" rel=\"noreferrer noopener\">RICHIESTA<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div><div class=\"layout_badh\"><div class=\"shizhezhao\" style=\"opacity:0.85;background-color:#ffffff;\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined bom15 top15\" id=\"\" style=\"background-color:#ffffff;padding-bottom:20px;padding-top:20px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<section class=\"wp-block-themepark-block-themepark-listbox thempark-block themepark_listbox  undefined padingmodle\" style=\"text-align:left;\"><h3 class=\"themepark_listbox_title\" style=\"color:#2ba8db;font-size:18px;padding-left:0%;padding-right:7%;\"><span>Download dei dati del prodotto<\/span><\/h3><ul class=\"themepark_listbox_list\" style=\"padding-left:0%;padding-right:7%;\"><li style=\"color:#666666;font-size:14px;line-height:24px;margin-bottom:10px;padding-left:29px;\"><a href=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2022\/06\/lneya-products-manual.pdf\"><i class=\"fas fa-file-pdf\" style=\"color:#2ba8db;line-height:24px\"><\/i><\/a><a href=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2022\/06\/lneya-products-manual.pdf\" style=\"color:#666666;font-size:14px;line-height:24px;margin-bottom:10px;\"><span>manuale.pdf<\/span><\/a><\/li><\/ul><div class=\"themepark_listbox_ba\" style=\"opacity:1;\"><\/div><\/section>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"804\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/banner-1024x804.jpg\" alt=\"\" class=\"wp-image-6827\" style=\"width:400px\" srcset=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/banner-1024x804.jpg 1024w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/banner-300x235.jpg 300w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/banner-768x603.jpg 768w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/banner.jpg 1096w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-monte-white-color has-themecolor-1-background-color has-text-color has-background has-link-color wp-elements-1945e4e02c714611b043e428dfb7f89b\">Controllo della temperatura nei processi di produzione e test dei semiconduttori<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il metodo di riscaldamento entro 40 \u2103 adotta un compressore per il riscaldamento a gas caldo completamente chiuso e la macchina funziona ininterrottamente per 24 ore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-monte-white-color has-vivid-red-background-color has-text-color has-background has-link-color wp-elements-b18a7e67423e6211fe75d1f9f2c67f47\">Garantire la stabilit\u00e0 e l'affidabilit\u00e0 del flusso complessivo del processo dei semiconduttori, dal front-end al back-end.<\/h2>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-text-align-center has-black-color has-text-color has-link-color wp-elements-4c5ad3009d1a56f83f598cc255e89b42 wp-block-paragraph\" style=\"letter-spacing:0.5px\"><\/p>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:16px;line-height:28px;color:#666666;background-color:#ffffff;padding:10px 15px;\"><h3 class=\"content-super-p-title\" style=\"font-size:18px;color:#ffffff;background-color:#146ba2;padding:10px 5px;\"><i class=\"fas fa-feather-alt\"><\/i>Descrizione del prodotto<\/h3>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:16px;line-height:28px;text-indent:2em;color:#666666; border:1px #333 solid;padding:10px 10px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-black-color has-text-color wp-block-paragraph\" style=\"font-size:18px\">Il dispositivo di controllo della temperatura dei semiconduttori Chiller \u00e8 utilizzato principalmente per il controllo preciso della temperatura nei processi di produzione e test dei semiconduttori. I suoi prodotti comprendono il controllo della temperatura del liquido fluorurato (minimo -100 gradi), il cambio rapido di temperatura del gas di raffreddamento e riscaldamento, il mandrino a cambio rapido di temperatura, la macchina di refrigerazione del gas a bassa temperatura (-120 gradi), l'unit\u00e0 di refrigerazione a raffreddamento diretto (-150 gradi), ecc. L'azienda applica vari algoritmi (PID, PID feedforward e algoritmo ad albero autocostruito model free) nel sistema per ottenere una risposta rapida e un'elevata precisione di controllo.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-04267f909a8dc22c2306495066e80e88 wp-block-paragraph\" style=\"font-size:18px\">  Informazioni importanti come la temperatura (pressione) di scarico e di aspirazione, la temperatura di condensazione, la temperatura (pressione) dell'acqua di raffreddamento, la temperatura (pressione) del liquido (gas) in ingresso e in uscita, la potenza elettrica, la corrente e la tensione di ciascun componente e il livello del serbatoio dell'acqua del refrigeratore sono tutti gestiti, monitorati e registrati in modo completo attraverso sensori collegati al sistema di controllo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color has-link-color wp-elements-7fb821243c273fddd89491e9976ca2e4 wp-block-paragraph\">Il metodo di riscaldamento entro 40 \u2103 adotta il riscaldamento a gas caldo del compressore.<\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color has-link-color wp-elements-ca4dc0b426eb8ccffee295ba20b9f46f wp-block-paragraph\">Il sistema di circolazione del refrigeratore adotta un design completamente chiuso e la pompa di circolazione adotta una pompa a trascinamento magnetico.<\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color has-link-color wp-elements-575f91bce9128a43a3998e9d71e779cc wp-block-paragraph\">Test all'elio del refrigeratore 100%, test delle norme di sicurezza 100% per garantire la sicurezza e l'affidabilit\u00e0 del sistema.<\/p>\n\n\n\n<p class=\"has-vivid-red-color has-text-color has-link-color wp-elements-5d6e6fe2eedd88cd9d0444cfe58f266b wp-block-paragraph\">Il refrigeratore fa funzionare la fotocopiatrice ininterrottamente per 24 ore a 100%.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"370\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/cooling-cmod-ccd.png\" alt=\"\" class=\"wp-image-6828\" srcset=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/cooling-cmod-ccd.png 480w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/cooling-cmod-ccd-300x231.png 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-vivid-red-color has-text-color has-link-color wp-elements-3057107009bc4598f20a51a3066f779c\" style=\"text-transform:capitalize\">refrigeratori che controllano la temperatura di lavorazione sulle apparecchiature Fab<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-monte-white-color has-themecolor-2-background-color has-text-color has-background has-link-color wp-elements-e0dfc70230a1489f2afdbbd06a6493d7 wp-block-paragraph\" style=\"font-size:18px\">Raffreddatore a canale singolo raffreddato ad aria, progettato principalmente per le macchine di incisione. Viene utilizzato per fornire un controllo indipendente della temperatura delle pareti laterali della camera.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:16px;line-height:28px;color:#666666;background-color:#ffffff;padding:20px 20px;\"><h3 class=\"content-super-p-title\" style=\"font-size:20px;color:#ffffff;background-color:#146ba2;padding:10px 5px;\">Dettagli sulla configurazione<\/h3>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<table border=\"1\" width=\"&quot;90%\" align=\"center\">\n<tbody>\n<tr>\n<td width=\"82\">\n<p><span style=\"color: #000000;\"><strong>Modello<\/strong><\/span><\/p>\n<\/td>\n<td width=\"76\">\n<p><strong><span style=\"color: #000000;\">FLTZ-002<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-002W<\/span><\/strong><\/p>\n<\/td>\n<td width=\"74\">\n<p><strong><span style=\"color: #000000;\">FLTZ-003<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-003W<\/span><\/strong><\/p>\n<\/td>\n<td width=\"80\">\n<p><strong><span style=\"color: #000000;\">FLTZ-004<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-004W<\/span><\/strong><\/p>\n<\/td>\n<td width=\"80\">\n<p><strong><span style=\"color: #000000;\">FLTZ-006<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-006W<\/span><\/strong><\/p>\n<\/td>\n<td width=\"85\">\n<p><strong><span style=\"color: #000000;\">FLTZ-008<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-008W<\/span><\/strong><\/p>\n<\/td>\n<td width=\"92\">\n<p><strong><span style=\"color: #000000;\">FLTZ-010<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-010W<\/span><\/strong><\/p>\n<\/td>\n<td width=\"92\">\n<p><strong><span style=\"color: #000000;\">FLTZ-015<\/span><\/strong><\/p>\n<p><strong><span style=\"color: #000000;\">FLTZ-015W<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Controllo della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"581\">\n<p>\u00a05\u2103\uff5e90\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Precisione della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"581\">\n<p>\u00b10.05\u2103 \u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Controllo del flusso\u00a0\u00a0<\/p>\n<\/td>\n<td colspan=\"2\" width=\"150\">\n<p>10\uff5e25L\/min 5bar max<\/p>\n<\/td>\n<td colspan=\"3\" width=\"246\">\n<p>15\uff5e45L\/min 6bar max<\/p>\n<\/td>\n<td colspan=\"2\" width=\"184\">\n<p>25\uff5e75L\/min 6bar max<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Capacit\u00e0 di refrigerazione@10\u2103<\/p>\n<\/td>\n<td width=\"76\">\n<p>\u00a06kw<\/p>\n<\/td>\n<td width=\"74\">\n<p>\u00a08kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>\u00a010kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>15 kw<\/p>\n<\/td>\n<td width=\"85\">\n<p>\u00a020kw<\/p>\n<\/td>\n<td width=\"92\">\n<p>\u00a025kw<\/p>\n<\/td>\n<td width=\"92\">\n<p>\u00a040kw<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Volume del liquido di circolazione interno<\/p>\n<\/td>\n<td width=\"76\">\n<p>4L<\/p>\n<\/td>\n<td width=\"74\">\n<p>5L<\/p>\n<\/td>\n<td width=\"80\">\n<p>6L<\/p>\n<\/td>\n<td width=\"80\">\n<p>8L<\/p>\n<\/td>\n<td width=\"85\">\n<p>10L<\/p>\n<\/td>\n<td width=\"92\">\n<p>12L<\/p>\n<\/td>\n<td width=\"92\">\n<p>20L<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Capacit\u00e0 del vaso di espansione<\/p>\n<\/td>\n<td width=\"76\">\n<p>10L<\/p>\n<\/td>\n<td width=\"74\">\n<p>10L<\/p>\n<\/td>\n<td width=\"80\">\n<p>15L<\/p>\n<\/td>\n<td width=\"80\">\n<p>15L<\/p>\n<\/td>\n<td width=\"85\">\n<p>20L<\/p>\n<\/td>\n<td width=\"92\">\n<p>25L<\/p>\n<\/td>\n<td width=\"92\">\n<p>35L<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Refrigerante<\/p>\n<\/td>\n<td colspan=\"7\" width=\"581\">\n<p>R410A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Refrigerante secondario<\/p>\n<\/td>\n<td colspan=\"7\" width=\"581\">\n<p>Olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, DI, ecc. (la temperatura di DI deve essere controllata al di sopra di 10 \u2103).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Interfacce di ingresso e di uscita<\/p>\n<\/td>\n<td width=\"76\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"74\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"85\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Uscita acqua di raffreddamento<\/p>\n<\/td>\n<td width=\"76\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"74\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"85\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1 1\/8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Portata dell'acqua di raffreddamento@20\u2103<\/p>\n<\/td>\n<td width=\"76\">\n<p>1,5 m\u00b3\/h<\/p>\n<\/td>\n<td width=\"74\">\n<p>2m\u00b3\/h<\/p>\n<\/td>\n<td width=\"80\">\n<p>2,5 m\u00b3\/h<\/p>\n<\/td>\n<td width=\"80\">\n<p>4m\u00b3\/h<\/p>\n<\/td>\n<td width=\"85\">\n<p>4,5 m\u00b3\/h<\/p>\n<\/td>\n<td width=\"92\">\n<p>5,6 m\u00b3\/h<\/p>\n<\/td>\n<td width=\"92\">\n<p>9m\u00b3\/h<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>alimentazione 380V<\/p>\n<\/td>\n<td width=\"76\">\n<p>3,5kW<\/p>\n<\/td>\n<td width=\"74\">\n<p>4kW<\/p>\n<\/td>\n<td width=\"80\">\n<p>5,5kW<\/p>\n<\/td>\n<td width=\"80\">\n<p>7kW<\/p>\n<\/td>\n<td width=\"85\">\n<p>9,5kW<\/p>\n<\/td>\n<td width=\"92\">\n<p>12kW<\/p>\n<\/td>\n<td width=\"92\">\n<p>16kW<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"82\">\n<p>Estensione della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"581\">\n<p>Aggiungendo un riscaldatore elettrico, \u00e8 possibile ampliare l'intervallo di temperatura da -25 \u2103 a 80 \u2103.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<table border=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td width=\"71\">\n<p><span style=\"color: #000000;\"><strong>Modello<\/strong><\/span><\/p>\n<\/td>\n<td width=\"80\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-202<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-202W<\/strong><\/span><\/p>\n<\/td>\n<td width=\"80\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-203<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-203W<\/strong><\/span><\/p>\n<\/td>\n<td width=\"80\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-204<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-204W<\/strong><\/span><\/p>\n<\/td>\n<td width=\"80\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-206<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-206W<\/strong><\/span><\/p>\n<\/td>\n<td width=\"85\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-208<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-208W<\/strong><\/span><\/p>\n<\/td>\n<td width=\"92\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-210<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-210W<\/strong><\/span><\/p>\n<\/td>\n<td width=\"92\">\n<p><span style=\"color: #000000;\"><strong>FLTZ-215<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>FLTZ-215W<\/strong><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Intervallo di temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>-25\u2103\uff5e90\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Precisione del controllo della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>\u00b10.05\u2103 \u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"71\">\n<p>Controllo del flusso\u00a0\u00a0<\/p>\n<\/td>\n<td colspan=\"2\" width=\"161\">\n<p>10\uff5e25L\/min \u00b10,3<\/p>\n<\/td>\n<td colspan=\"3\" width=\"246\">\n<p>15\uff5e45L\/min \u00b10,3<\/p>\n<\/td>\n<td colspan=\"2\" width=\"184\">\n<p>25\uff5e75L\/min \u00b10,3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"592\">\n<p>Il controllo del flusso \u00e8 regolato da un convertitore di frequenza e la pressione massima della pompa di circolazione \u00e8 di 5 bar.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Refrigerazione<\/p>\n<p>@-15\u2103<\/p>\n<\/td>\n<td width=\"80\">\n<p>2kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>3kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>3,8kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>6kw<\/p>\n<\/td>\n<td width=\"85\">\n<p>7,6kw<\/p>\n<\/td>\n<td width=\"92\">\n<p>10kw<\/p>\n<\/td>\n<td width=\"92\">\n<p>15kw<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Circolazione interna Volume del fluido<\/p>\n<\/td>\n<td width=\"80\">\n<p>4L<\/p>\n<\/td>\n<td width=\"80\">\n<p>5L<\/p>\n<\/td>\n<td width=\"80\">\n<p>6L<\/p>\n<\/td>\n<td width=\"80\">\n<p>8L<\/p>\n<\/td>\n<td width=\"85\">\n<p>10L<\/p>\n<\/td>\n<td width=\"92\">\n<p>12L<\/p>\n<\/td>\n<td width=\"92\">\n<p>20L<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Volume del vaso di espansione<\/p>\n<\/td>\n<td width=\"80\">\n<p>10L<\/p>\n<\/td>\n<td width=\"80\">\n<p>10L<\/p>\n<\/td>\n<td width=\"80\">\n<p>15L<\/p>\n<\/td>\n<td width=\"80\">\n<p>15L<\/p>\n<\/td>\n<td width=\"85\">\n<p>20L<\/p>\n<\/td>\n<td width=\"92\">\n<p>25L<\/p>\n<\/td>\n<td width=\"92\">\n<p>35L<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>refrigerante<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>R404A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Refrigerante secondario<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>Acqua, olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, ecc.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Interfaccia di ingresso e di uscita<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"85\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Collegamento all'acqua di raffreddamento<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"85\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1 1\/8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Flusso d'acqua di raffreddamento@20\u2103<\/p>\n<\/td>\n<td width=\"80\">\n<p>1,2 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"80\">\n<p>1,6 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"80\">\n<p>2,6 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"80\">\n<p>3,6 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"85\">\n<p>5,5 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"92\">\n<p>7m\u00b3\/H<\/p>\n<\/td>\n<td width=\"92\">\n<p>10,2 m\u00b3\/H<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Potenza 380V<\/p>\n<\/td>\n<td width=\"80\">\n<p>3KW<\/p>\n<\/td>\n<td width=\"80\">\n<p>4KW<\/p>\n<\/td>\n<td width=\"80\">\n<p>6KW<\/p>\n<\/td>\n<td width=\"80\">\n<p>8KW<\/p>\n<\/td>\n<td width=\"85\">\n<p>9KW<\/p>\n<\/td>\n<td width=\"92\">\n<p>13KW<\/p>\n<\/td>\n<td width=\"92\">\n<p>17KW<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Espansione della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>Aggiungendo un riscaldatore elettrico, la temperatura pu\u00f2 essere estesa a -25\u2103~80\u2103.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<table border=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td width=\"71\">\n<p><strong>Modello<\/strong><\/p>\n<\/td>\n<td width=\"80\"><strong>FLTZ-402FLTZ-402W<\/strong><\/td>\n<td width=\"80\"><strong>FLTZ-403FLTZ-403W<\/strong><\/td>\n<td width=\"80\"><strong>FLTZ-404FLTZ-404W<\/strong><\/td>\n<td width=\"80\"><strong>FLTZ-406FLTZ-406W<\/strong><\/td>\n<td width=\"85\"><strong>FLTZ-408FLTZ-408W<\/strong><\/td>\n<td width=\"92\"><strong>FLTZ-410FLTZ-410W<\/strong><\/td>\n<td width=\"92\"><strong>FLTZ-415FLTZ-415W<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Controllo della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\u00a0<span style=\"color: #333333;\">-45\u2103\uff5e90\u2103<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Precisione del controllo della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>\u00b10.05\u2103 \u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Controllo del flusso\u00a0\u00a0<\/p>\n<\/td>\n<td colspan=\"2\" width=\"161\">\n<p>10\uff5e25L\/min 5bar max<\/p>\n<\/td>\n<td colspan=\"3\" width=\"246\">\n<p>15\uff5e45L\/min 6bar max<\/p>\n<\/td>\n<td colspan=\"2\" width=\"184\">\n<p>25\uff5e75L\/min 6bar max<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Riscaldamento<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>Il riscaldamento del compressore viene utilizzato per prevenire la tecnologia di congelamento del condensatore.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Capacit\u00e0 di refrigerazione<\/p>\n<p>@-35\u2103<\/p>\n<\/td>\n<td width=\"80\">\n<p>1kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>1,4kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>1,8kw<\/p>\n<\/td>\n<td width=\"80\">\n<p>2,5kw<\/p>\n<\/td>\n<td width=\"85\">\n<p>3,3kw<\/p>\n<\/td>\n<td width=\"92\">\n<p>5kw<\/p>\n<\/td>\n<td width=\"92\">\n<p>8kw<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Volume del fluido di circolazione interno<\/p>\n<\/td>\n<td width=\"80\">\n<p>4L<\/p>\n<\/td>\n<td width=\"80\">\n<p>5L<\/p>\n<\/td>\n<td width=\"80\">\n<p>6L<\/p>\n<\/td>\n<td width=\"80\">\n<p>8L<\/p>\n<\/td>\n<td width=\"85\">\n<p>10L<\/p>\n<\/td>\n<td width=\"92\">\n<p>12L<\/p>\n<\/td>\n<td width=\"92\">\n<p>20L<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Volume del vaso di espansione<\/p>\n<\/td>\n<td width=\"80\">\n<p>10L<\/p>\n<\/td>\n<td width=\"80\">\n<p>10L<\/p>\n<\/td>\n<td width=\"80\">\n<p>15L<\/p>\n<\/td>\n<td width=\"80\">\n<p>15L<\/p>\n<\/td>\n<td width=\"85\">\n<p>20L<\/p>\n<\/td>\n<td width=\"92\">\n<p>25L<\/p>\n<\/td>\n<td width=\"92\">\n<p>35L<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Refrigerante<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>R404A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Refrigerante secondario<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>Acqua, olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, ecc.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Interfaccia di ingresso e di uscita<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"85\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG3\/4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Collegamento all'acqua di raffreddamento<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1\/2<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG3\/4<\/p>\n<\/td>\n<td width=\"80\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"85\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1<\/p>\n<\/td>\n<td width=\"92\">\n<p>ZG1 1\/8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Flusso di acqua di raffreddamento @20\u2103<\/p>\n<\/td>\n<td width=\"80\">\n<p>1,5m\u00b3\/H<\/p>\n<\/td>\n<td width=\"80\">\n<p>2,4 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"80\">\n<p>3,5 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"80\">\n<p>5m\u00b3\/H<\/p>\n<\/td>\n<td width=\"85\">\n<p>5,5 m\u00b3\/H<\/p>\n<\/td>\n<td width=\"92\">\n<p>6m\u00b3\/H<\/p>\n<\/td>\n<td width=\"92\">\n<p>8m\u00b3\/H<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Potenza 380V<\/p>\n<\/td>\n<td width=\"80\">\n<p>3KW<\/p>\n<\/td>\n<td width=\"80\">\n<p>4KW<\/p>\n<\/td>\n<td width=\"80\">\n<p>6KW<\/p>\n<\/td>\n<td width=\"80\">\n<p>7,5KW<\/p>\n<\/td>\n<td width=\"85\">\n<p>9KW<\/p>\n<\/td>\n<td width=\"92\">\n<p>12KW<\/p>\n<\/td>\n<td width=\"92\">\n<p>15KW<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"71\">\n<p>Espansione della temperatura<\/p>\n<\/td>\n<td colspan=\"7\" width=\"592\">\n<p>Aggiungendo un riscaldatore elettrico, la temperatura pu\u00f2 essere estesa a -25\u2103~80\u2103.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"880\" height=\"466\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_02-1.jpg\" alt=\"\" class=\"wp-image-8924\" style=\"width:750px\" srcset=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_02-1.jpg 880w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_02-1-300x159.jpg 300w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_02-1-768x407.jpg 768w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_02-1-18x10.jpg 18w\" sizes=\"auto, (max-width: 880px) 100vw, 880px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"880\" height=\"554\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_03-2.jpg\" alt=\"\" class=\"wp-image-8925\" style=\"width:750px\" srcset=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_03-2.jpg 880w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_03-2-300x189.jpg 300w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_03-2-768x483.jpg 768w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_03-2-18x12.jpg 18w\" sizes=\"auto, (max-width: 880px) 100vw, 880px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"880\" height=\"496\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_04-1.jpg\" alt=\"\" class=\"wp-image-8926\" style=\"width:750px\" srcset=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_04-1.jpg 880w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_04-1-300x169.jpg 300w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_04-1-768x433.jpg 768w, https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/880_04-1-18x10.jpg 18w\" sizes=\"auto, (max-width: 880px) 100vw, 880px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:22px\">Funzione di comunicazione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-vivid-red-color has-text-color has-link-color wp-elements-7345dd33b9df3949607853ab7afff727\">Standard equipment includes serial<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<p class=\"has-text-align-center has-black-color has-text-color has-link-color wp-elements-ca8c30b51c4c35bbb96bcd96c17f2912 wp-block-paragraph\" style=\"font-size:18px\">Communication (RS232C, RS485) and contact input\/output. Can communicate with customer devices or build systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/04\/flt6.jpg\" alt=\"\" class=\"wp-image-7836\" style=\"width:750px\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-black-color has-text-color has-link-color wp-elements-a60f0ce00f9859a4a8573bf87913c933\" style=\"font-size:18px;text-transform:capitalize\">segnale di uscita del cliente<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:5%\"><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center has-black-color has-text-color has-link-color wp-elements-f38be9779de9644629023077126305ff wp-block-paragraph\" style=\"font-size:18px\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-themepark-block-themepark-comment thempark-block themepark-comment undefined\" style=\"padding-bottom:20px;padding-top:20px;\"><div class=\"themepark-comment_in\" id=\"ud_form\"><div class=\"themepark-comment_inb2\"><div class=\"themepark-comment_inb\" style=\"\"><div class=\"themepark-comment_form nolable\" style=\"\"><div class=\"fromtts\" style=\"\"><span class=\"fromtt\" style=\"font-size:26px;\">Invia la tua richiesta e ti contatteremo entro 24 ore<\/span><\/div><form id=\"commentform-park\" class=\"themepark-c-f twomo  inquirylist\" action=\"https:\/\/tw.lneya.com\/wp-comments-post.php\" method=\"post\" autocomplete=\"off\" data-trp-original-action=\"https:\/\/tw.lneya.com\/wp-comments-post.php\"><div class=\"themepark-comment_form_box tptext\" style=\"font-size:14px;\"><lable for=\"tpcommet0\" class=\"required\"><input type=\"text\" id=\"tpcommet0\" name=\"tpcommet0\" size=\"28\" required style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\" placeholder=\"Nome\"\/><span class=\"required\">*<div class=\"required_tishi animated\"><i class=\"fas fa-exclamation-circle\"><\/i><span><\/span><\/div><\/span><\/lable><\/div><div class=\"themepark-comment_form_box tptext mail-c\" style=\"font-size:14px;\"><lable for=\"tpcommet1\" class=\"required\"><input type=\"text\" class=\"f-email\" id=\"tpcommet1\" name=\"tpcommet1\" size=\"28\" required style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\" placeholder=\"Indirizzo e-mail\"\/><span class=\"required\">*<div class=\"required_tishi animated\"><i class=\"fas fa-exclamation-circle\"><\/i><span><\/span><\/div><\/span><\/lable><\/div><div class=\"themepark-comment_form_box tptext\" style=\"font-size:14px;\"><lable for=\"tpcommet2\" class=\"\"><input type=\"text\" id=\"tpcommet2\" name=\"tpcommet2\" size=\"28\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\" placeholder=\"Azienda\"\/><\/lable><\/div><div class=\"themepark-comment_form_box tptext\" style=\"font-size:14px;\"><lable for=\"tpcommet3\" class=\"\"><input type=\"text\" id=\"tpcommet3\" name=\"tpcommet3\" size=\"28\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\" placeholder=\"Campo di controllo della temperatura\"\/><\/lable><\/div><div class=\"themepark-comment_form_box tprideo\" style=\"font-size:14px;\"><lable for=\"tpcommet4\" class=\"rideos\"><p class=\"msspan\" style=\"color: #146ba2;\">Multicanale<\/p><lable class=\"rideo\" for=\"tpcommet40\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input autocomplete=\"off\" type=\"radio\" name=\"tpcommet4\" id=\"tpcommet40\" value=\"Channel 1\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>Canale 1<\/lable><lable class=\"rideo\" for=\"tpcommet41\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input autocomplete=\"off\" type=\"radio\" name=\"tpcommet4\" id=\"tpcommet41\" value=\"Channel 2\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>Canale 2<\/lable><lable class=\"rideo\" for=\"tpcommet42\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input autocomplete=\"off\" type=\"radio\" name=\"tpcommet4\" id=\"tpcommet42\" value=\"Channel 3\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>Canale 3<\/lable><\/lable><\/div><div class=\"themepark-comment_form_box tpcheckbox\" style=\"font-size:14px;\"><lable for=\"tpcommet5\" class=\"checkboxs required\"><p class=\"msspan\" style=\"color: #146ba2;\">Tensione<\/p><lable autocomplete=\"off\" class=\"rideo\" for=\"tpcommet50\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input type=\"checkbox\" name=\"tpcommet5[]\" id=\"tpcommet50\" value=\"50HZ single phase\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>50HZ monofase<\/lable><lable autocomplete=\"off\" class=\"rideo\" for=\"tpcommet51\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input type=\"checkbox\" name=\"tpcommet5[]\" id=\"tpcommet51\" value=\"50HZ three phase\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>50HZ trifase<\/lable><lable autocomplete=\"off\" class=\"rideo\" for=\"tpcommet52\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input type=\"checkbox\" name=\"tpcommet5[]\" id=\"tpcommet52\" value=\"60HZ single phase\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>60HZ monofase<\/lable><lable autocomplete=\"off\" class=\"rideo\" for=\"tpcommet53\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\"><input type=\"checkbox\" name=\"tpcommet5[]\" id=\"tpcommet53\" value=\"60HZ three phase\"\/><span class=\"active\"><i class=\"fas fa-caret-right\"><\/i><\/span>60HZ trifase<\/lable><span class=\"required\">*<div class=\"required_tishi animated\"><i class=\"fas fa-exclamation-circle\"><\/i><span><\/span><\/div><\/span><\/lable><\/div><div class=\"themepark-comment_form_box tpTextarea\" style=\"font-size:14px;\"><lable for=\"tpcommet6\"><textarea id=\"tpcommet6\" name=\"tpcommet6\" style=\"color:#616161;border: solid 1px #146ba2;background-color: #ffffff;\" placeholder=\"Altri dettagli che vuoi dirci...\"><\/textarea><\/lable><\/div><div class=\"hiddeninput\"><input name=\"comment_post_ID\" type=\"hidden\" value=\"6825\"\/><input name=\"author\" type=\"hidden\" class=\"author\"\/><input name=\"email\" type=\"hidden\" class=\"email\"\/><textarea name=\"comment\" style=\"display:none\" class=\"comment\"><\/textarea><input name=\"themeparklable\" type=\"hidden\" value=\"Name|Email Address|Company|Temp control range|Multi-channel|Voltage|Others you want to tell us...\"\/><input name=\"themeparktype\" type=\"hidden\" value=\"text|text2|text|text|rideo|checkbox|Textarea\"\/><input name=\"redirect_to\" type=\"hidden\" value=\"https:\/\/tw.lneya.com\"\/><input name=\"inquiryid\" type=\"hidden\"\/><input name=\"inquirytime\" type=\"hidden\"\/><input name=\"position\" type=\"hidden\"\/><\/div><div class=\"submut_box\"><input type=\"submit\" class=\"submut_btn\" name=\"submit\" style=\"background:#146ba2;\" value=\"Invia una richiesta\"\/><div class=\"tishi\" style=\"color:#070707;\"><div class=\"loading\" style=\"color:#616161;\"><i class=\"fas fa-spinner\"><\/i>Invio....<\/div><div class=\"success\" style=\"color:#616161;\"><i class=\"fas fa-check\"><\/i>Inviato con successo!<\/div><div class=\"erro\" style=\"color:#616161;\"><i class=\"fas fa-exclamation-circle\"><\/i>Invio fallito! Riprovare pi\u00f9 tardi<\/div><div class=\"e-email\">Errore e-mail!<\/div><div class=\"e-tel\">Errore telefonico!<\/div><\/div><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"it\"\/><\/form><\/div><div class=\"wp_clear\"><\/div><\/div><div class=\"themepark-comment_in_b\" style=\"opacity:0.83;background-color:#ffffff;transform:scaleX(1.02) scaleY(1.042)\"><\/div><\/div><\/div><div class=\"wp_clear\"><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-monte-white-color has-text-color has-background has-medium-font-size\" style=\"background-color:#146ba2;text-transform:capitalize\">consigliare i prodotti<\/h2>\n\n\n<div id=\"post_in_list2\" class=\"post_in_list_out\" style=\"margin-bottom:20px;\"><ul class=\"post_in_list row4  nobig\" data-cat=\"\"data-tag=\"\"data-nb=\"4\"data-rand=\"\"data-page=\"2\" data-modle=\"post_in_list2\"data-pbtn=\"\"data-pbtnicon=\"\"data-seo2=\"\"data-wtitlesize=\"16\"data-wtitlecolor=\"\"data-wtitlehight=\"63\"data-btncolor=\"\"data-first=\"\"data-b2=\"\"data-b1=\"0\"data-row=\"4\"data-canshu=\"0\"data-wtitlecolor2=\"\"data-home=\"https:\/\/tw.lneya.com\/it\"><\/ul><div class=\"tishi\"><p class=\"loading\"><i class=\"fas fa-spinner\"><\/i>caricamento...<\/p><p class=\"lasetpost\">\u5df2\u7ecf\u662f\u5230\u6700\u540e\u4e00\u7bc7\u5185\u5bb9\u4e86\uff01<\/p><\/div><\/div><\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>","protected":false},"excerpt":{"rendered":"<p>Precisione della temperatura<br \/>\n\u00b10.1\u2103<br \/>\nControllo del flusso<br \/>\n25~75\/min 6bar max<br \/>\nRefrigent<br \/>\nR404A<br \/>\nGamma di potenza<br \/>\n380V 3,5kW~16kW<\/p>","protected":false},"author":1,"featured_media":6826,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":true,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":true,"footnotes":""},"categories":[1],"tags":[80,156],"class_list":["post-6825","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-cooling-chiller","tag-semiconductor-chiller"],"metadata":{"themepark_paddingblock":["1"],"themepark_post_hide_title":["1"],"_thumbnail_id":["6826"],"catce":["sidebar-widgets4"],"views":["3647"],"_dp_original":["6798"],"_edit_lock":["1732165774:1"],"_edit_last":["1"],"themepark_seo_title":[""],"themepark_seo_description":[""],"themepark_seo_keyword":[""]},"taxonomy_info":{"category":[{"value":1,"label":"\u672a\u5206\u7c7b"}],"post_tag":[{"value":80,"label":"cooling chiller"},{"value":156,"label":"semiconductor chiller"}]},"featured_image_src_large":["https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/chiller2.jpg",450,450,false],"author_info":{"display_name":"lneyaadmindy","author_link":"https:\/\/tw.lneya.com\/it\/author\/lneyaadmindy"},"comment_info":0,"category_info":[{"term_id":1,"name":"\u672a\u5206\u7c7b","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":152,"filter":"raw","cat_ID":1,"category_count":152,"category_description":"","cat_name":"\u672a\u5206\u7c7b","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":80,"name":"cooling chiller","slug":"cooling-chiller","term_group":0,"term_taxonomy_id":80,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw"},{"term_id":156,"name":"semiconductor chiller","slug":"semiconductor-chiller","term_group":0,"term_taxonomy_id":156,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw"}],"medium_url":"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/chiller2-300x300.jpg","thumbnail_url":"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/chiller2-150x150.jpg","full_url":"https:\/\/tw.lneya.com\/wp-content\/uploads\/2024\/02\/chiller2.jpg","_links":{"self":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/posts\/6825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/comments?post=6825"}],"version-history":[{"count":0,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/posts\/6825\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/media\/6826"}],"wp:attachment":[{"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/media?parent=6825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/categories?post=6825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tw.lneya.com\/it\/wp-json\/wp\/v2\/tags?post=6825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}