空冷チラーにおける蒸発器の機能
The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water quality, and saves water resources. It is the most economical and simple machine for maintenance and repair in the current refrigeration equipment. The one-time investment of air-cooled chiller is slightly higher than that of water-cooled chiller, but the annual operation cost is lower than that of water-cooled chiller. The construction cost of machine room is the least among various cold and heat source systems, and the maintenance cost is about half of that of water-cooled chiller.
When the temperature of air or other fluid decreases, the pressure in the temperature sensing bag decreases. The valve port of the temperature control pilot valve is closed, and the refrigerant gas flow from the evaporator to the main regulating valve decreases. When the pressure at the top of the main piston is discharged into the suction pipe of the compressor, the main spring closes the main valve. In the air-cooled chiller system, when the evaporator pressure regulating valve is used to control the temperature, the temperature control pilot valve should be used to replace the pressure control pilot valve introduced earlier, so that the temperature of air or other fluids flowing through the evaporator can be accurately maintained at a predetermined value.
The evaporator is one of the four major components in the chiller system. The evaporator plays a role in heat dissipation in the chiller system. Connect the temperature control pilot valve with the joint of the outer pressure guide hole of the evaporator pressure regulating valve, and place the temperature sensing package of the pilot valve in the air flow or flowing medium to control its temperature. When the temperature of air or other medium increases, the pressure in the temperature sensing package increases, and the valve port of the temperature control pilot valve opens, so the evaporator pressure is transmitted to the space at the top of the main regulating valve piston through the outer pressure guide pipe, Press down the piston and open the main regulating valve. The evaporator pressure then drops to an appropriate value, which increases the temperature difference between air or other fluids and refrigerant, and improves the refrigeration capacity of the evaporator of the low-temperature chiller.
関連推奨品
-
冷暖房システムはどのようにして同時温度制御を実現しているのですか?
2001温度制御システム サーモスタットは暖房と冷房機能を持ち、-120℃~320℃の連続温度制御のために同じ媒体を使用することができます。冷暖房システムの冷暖房システムは、主に4つの部品で構成されています。
詳細を見る -
極低温冷凍システムに対する間違った理解
2405Compressor and system matching should be matched reasonably When the compressor of cryogenic refrigeration system is replaced, the large size of the compressor does not represent goodness, and the matching between the compressor and the system sho...
詳細を見る -
周囲温度を下げることでバッテリーの寿命を延ばすことは正しいのか?
1872バッテリーは広い温度範囲で動作するが、高温条件下での充電はできない。充電プロセスは放電プロセスよりもデリケートであり、細心の注意が必要です。極端な低温...
詳細を見る -
超低温工業用冷蔵庫でのベアリングの冷間組立に関する説明書
1869超低温工業用冷蔵庫の冷凍システムは、一般的にカスケード冷凍の作動原理を採用し、2つの完全密閉式コンプレッサーが高温コンプレッサーと低温コンプレッサーとして使用される。コンプレッサーの銅管は...
詳細を見る
工業冷水機製造商 LNEYA Taiwan