If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of the expansion valve is often due to lack of cooling. Or the expansion valve flow is not enough, too little refrigerant expansion will not use all the evaporator area, only the low temperature is formed locally in the evaporator, and some areas are rapidly expanded due to the small amount of refrigerant, causing the local temperature to be too low, and the evaporator appears. Frosting.

After local frosting, due to the formation of a thermal insulation layer on the surface of the evaporator, the heat exchange amount in the area is low, the expansion of the refrigerant is transferred to other areas, and the entire evaporator is frosted or frozen, and the entire evaporator is insulated. The layer, then the expansion spreads to the compressor return pipe causing the compressor to return to the air. Since the amount of refrigerant is too small, the evaporation pressure of the evaporator is low, resulting in low evaporation temperature, which will gradually lead to condensation of the evaporator to form a heat insulation layer and transfer the expansion point to the compressor return air to cause the compressor to return to the air. All of the above points will show the evaporator frosting before the compressor of the new energy vehicle battery test system returns to air.

Importance of refrigerants in new energy vehicle battery test systems(images 1)

If the new energy vehicle battery test system has a heat bypass valve, then just adjust the hot gas bypass valve. The specific method: open the rear end cover of the hot gas bypass valve, and then use the 8th hex wrench to turn the adjustment inside the clockwise Nut, the adjustment process should not be too fast, generally pause for about half a circle, let the system run for a period of time to see the frost condition and then decide whether to continue to adjust. After the operation is stable, the compressor frosting phenomenon disappears and the end cap is tightened. For models below 15 cubic meters, since there is no hot gas bypass valve, if the frosting phenomenon is serious, the take-off pressure of the pressure switch of the condensing fan can be appropriately adjusted.

Specific method: first find the pressure switch, remove the adjustment nut of the pressure switch to fix the small piece, and then use a Phillips screwdriver to rotate clockwise, the whole adjustment also needs to be carried out slowly, adjust a half circle to see the situation and then decide whether it needs adjustment.

Therefore, the refrigerant in the new energy vehicle battery test system is very important. Secondly, the choice of refrigerant is also very important. The mixed refrigerants of professional manufacturers of production equipment have certain advantages in performance, so it is recommended that users choose according to their own needs.

前の記事 次だ:

関連推奨品

  • 工業用冷水システムの仕組み

    2347

    産業機械を使用する際、機械の過熱を防ぐために冷却装置が必要になることがある。冷凍装置は材料を最適な温度範囲に効果的に保つことができるが、冷却装置はどのように機能するのだろうか。冷凍機の仕組みを理解することで、機械が最適な温度範囲に保たれるようになります。

    詳細を見る
  • LNEYA精密冷凍機の応用範囲

    2152

    LNEYA精密冷凍機の主な応用産業は、プラスチック産業、電子産業、電気メッキ産業、医療産業、食品産業、真空コーティング産業などです。これらの産業は主な応用産業である。

    詳細を見る
  • 工業用冷水機システムの選び方

    2181

    Want to buy an industrial water chiller system? Want to buy a reliable industrial water chiller system? Want to buy a high-quality industrial water chiller system? How to buy? 1. Process requirements Regardless of equipment, LNEYA provides users...

    詳細を見る
もっと拡大する!