高温と低温の閉ループ循環機を設置する際に注意すべき点は?
There are certain differences in the size and performance of high and low temperature fully enclosed circulators from different manufacturers. Users need to pay attention to the placement position when placing them after purchase. If the placement position is not good, it is not conducive to the operation of high and low temperature fully enclosed circulators.
In the installation of high and low temperature fully enclosed circulators, the heat dissipation efficiency of the high and low temperature closed loop circulators should be considered and the maintenance should be easy. The floor of the equipment must be flat and have sufficient strength (3.4 N/m2 or higher). Select a dust. And locations where vibration effects are small.
High and low temperature fully enclosed circulators are to be installed in a dry room with a high and low temperature fully enclosed circulator, and where there is a power supply and sewer nearby, the equipment should be installed in a place with little dust. The wind condition causes no oxygen deficiency to occur even if the refrigerant (fluorohydrocarbon) leaks from the equipment.
Good ventilation should be maintained around the installation of high and low temperature fully enclosed circulators. During operation, the device will radiate heat. If it is air-cooled, it will directly discharge heat through the condensed air. In the case of small room and poor ventilation, the indoor temperature will rise rapidly, causing the machine to stop running and alarm. . Installation of high and low temperature fully enclosed circulators should be kept away from flammable or explosive materials or other substances that may generate high heat.
When placing it, be careful not to let the sun directly project onto the device. When the device is used beyond this range, the safety device will start or the device will stop running. In order to achieve stable performance of the high and low temperature closed loop circulator, the installation room of the high and low temperature closed loop circulator should be air-conditioned to maintain the indoor temperature between 10 ° C and 30 ° C.
The atmospheric environment of the high and low temperature fully enclosed circulator installation site is consistent with the general indoor air-conditioned atmospheric environment. If organic solvents, plasticizers, acids, alkalis or other chemicals are present in the air, the parts or coatings of the equipment may be corroded and destroyed.
The precautions for placing the high and low temperature fully enclosed circulators should be taken seriously by our operators. Read the instruction manual in detail.
関連推奨品
-
産業用冷凍機の冷凍特性とは?
2124入口と出口の水の温度差が大きい場合は、大きな外部タンクを使用して冷水を貯蔵する。この場合、冷却水はクーラーから直接供給されることはない。クーラーの外側の奥深く...
詳細を見る -
100ワットの水のリターナーが1ヶ月にどれだけの電力を浪費するか見てみよう。
2202Our daily electricity consumption counting is calculated by "kilowatt-hour". One kilowatt-hour is one kilowatt-hour. We first convert the power into kilowatt-hour, then multiply it by time. Take the above 100-watt as an example, 100-watt is 0.1 ki...
詳細を見る -
産業用超低温フリーザーの高圧アラームをなくすには?
1710使用中、故障が時間内に解決されないと、工業用超低温冷凍庫の使用に影響します。高圧アラームの問題を解決するには?もし水冷式工業用超低温フリーザーが高圧アラームを発した場合、その故障を解決しなければ、工業用超低温フリーザーの使用に支障をきたします。
詳細を見る -
冷凍・暖房循環システムにおけるTCUの応用
2270医薬品の合成やファインケミカルの工程では、酸化反応や酸塩基の中和反応など、強い発熱反応に遭遇することが多い。このような強い発熱反応では、制御が不適切であったり、...
詳細を見る
工業冷水機製造商 LNEYA Taiwan











