密閉式冷凍加熱サーキュレーター日常のメンテナンスマニュアル
異なるメーカーの密閉式冷凍・加熱サーキュレーターには一定の寿命があります。密閉式冷凍・加熱サーキュレーターの合理的で正しい操作とメンテナンスは、効果的に耐用年数を延ばすことができます。ユーザー...
The user regularly maintains the closed refrigeration heating circulator, promptly eliminates the instrument failure, and makes maintenance records. The large equipment is cleaned and maintained 2-4 times per semester. The damaged closed refrigeration heating circulator should be overhauled by the equipment manufacturer’s professional. If external repair is required, the application should be submitted to the equipment. Equipment management personnel should strive to learn business and improve the level of management, maintenance and maintenance. Conduct regular inspections according to the specifications specified by the instrument or the performance indicators during commissioning, and register for future reference.
When the closed refrigeration heating circulator is turned on, it should be seen whether the steering of the fan is accurate. If the forward rotation can be started, the reverse rotation indicates that the power supply wiring is reversed, and the phase sequence must be replaced before starting. The setting values of each protection device are high and low temperature cycle. The factory has been set up, and users should not change it at will.
When the closed cooling and heating circulator is stopped, press the stop button to check the cause of the high fault. Do not force the machine to run before the fault is eliminated. If you use it for a long time in the winter, turn off the main power and drain the water in the system. It is necessary to keep the machine room clean and ventilated well, and carry out the cleaning and removing work of the condenser on schedule to ensure that the refrigeration and heating integrated machine does not work normally.
When using a closed refrigeration heating circulator, it is also necessary to pay attention to the selection of materials made of materials that are resistant to high temperature and corrosion resistant processes. In general, when using a closed refrigeration heating circulator, the temperature is in the range of 100 ° C – 300 ° C, the heating temperature is different, the oil used is also different, glycerin, paraffin oil, silicone oil, vacuum pump oil or some vegetable oil Yes, you can choose the right oil based on their heating temperature.
Closed refrigeration heating circulators provide corresponding cold sources in the pharmaceutical, chemical, biological and other industries. As a constant temperature source, the performance requirements are self-evident, so we must pay attention to the necessary maintenance.
関連推奨品
-
完全に密閉された冷暖房サーモスタットの冷媒アラーム不足の解決策
2333完全密閉式冷暖房サーモスタットが冷媒不足でアラームを発した場合、どうすればよいですか?多くのお客さまがこの問題に遭遇すると思います。実は、これは比較的簡単なことなのです。原理さえわかっていれば・・・。
詳細を見る -
原子炉温度サイクル制御装置を選ぶ際に注意すべき点
1864The temperature circulation control machine of the reaction kettle has always been an indispensable equipment for pharmaceutical and chemical enterprises. As a refrigeration and heating experimental equipment, if the purchased reactor temperature ...
詳細を見る -
大型冷凍機の消費電力の理由は?
1886大型冷凍機の運転中、冷却能力と作業条件が電力消費の主な問題となるが、無駄な電力消費を避けるためには、明確に理解する必要がある。規模が大きくなると、消費電力は大きくなる。
詳細を見る -
Temperature conditions of new energy vehicle batteries
1828When automobile manufacturers continue to improve battery life to overcome the driver's mileage anxiety, the energy density of the large batteries installed is also gradually increasing, which means that the temperature monitoring function of the...
詳細を見る
工業冷水機製造商 LNEYA Taiwan