温冷一体型コントロールマシンの設置はどうする?
Since the thermocouple’s thermal inertia causes the meter’s indicated value to lag behind the measured temperature, this effect is particularly pronounced when performing rapid measurements. Therefore, thermocouples with thinner thermal electrodes and smaller protective tube diameters should be used whenever possible. The protective tube can even be removed when the temperature measurement environment permits.
In the use of hot and cold integrated control machine, usually use materials with good thermal conductivity, thin tube, small inner diameter protection sleeve, in the more precise temperature measurement, use unprotected sleeved bare wire thermocouple, but thermocouple It is easy to damage and should be corrected and replaced in time.
Due to the measurement lag, the amplitude of the temperature fluctuation detected by the thermocouple is smaller than the amplitude of the furnace temperature fluctuation. In order to accurately measure the temperature, a thermocouple with a small time constant should be selected. The time constant is inversely proportional to the heat transfer coefficient. It is proportional to the diameter of the hot end of the thermocouple, the density of the material, and the specific heat. If the time constant is to be reduced, In addition to the thermal coefficient, the error introduced by the insulation of the cold and heat integrated control machine is poor.
The hot and cold integrated control machine protects the tube and the wire plate from excessive dirt or salt residue, resulting in poor insulation between the thermocouple and the furnace wall, which is more serious at high temperatures, which not only causes the loss of the thermoelectric potential but also introduces interference. The error caused by this can sometimes reach Baidu.
The above installation failures should be avoided as much as possible to reduce the error rate of the integrated heat and cold control machine and save the operating cost of the enterprise.
関連推奨品
-
原子炉の自動温度制御システムの不具合を解決するには?
2154原子炉の自動温度制御システムの性能は非常に重要です。起動できないような故障に遭遇したら、できるだけ早くそれを解決しなければならない。
詳細を見る -
Application of Industrial Air-Cooled Chiller in Chemical Industry
2247Industrial air-cooled chillers are applicable to glass reactors, metal reactors and bioreactors for temperature control. In the field of chemistry and pharmacy, air-cooled chillers usually carry out necessary temperature control together with the ...
詳細を見る -
グリコールチラーシステムを長持ちさせるには?
1898工業用グリコールチラーを長寿命化するために、以下の点にご注意ください:1.1.自動車グレードの不凍液は慎重に使用してください自動車グレードの不凍液や不適格な不凍液は使用しないでください。なぜなら、このグリ...
詳細を見る -
冷暖房温度制御システムの選び方
2118冷凍暖房温度制御システムの価格は主な要因ではない。主な目的は、温度制御機能を通じて温度制御技術を実装することです。しかし、それは温度制御システムではない。
詳細を見る