完全に密閉された冷暖房サーモスタットの冷媒アラーム不足の解決策
What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle of the lack of refrigerant alarm, it can be solved very well. Today I will share two points with you so that everyone will encounter this problem. It can be solved very quickly.
When we encounter a refrigerant shortage alarm in a fully enclosed heating and cooling thermostat, the first thing we have to do is to check to see if the liquid level on the expansion tank of the fully enclosed heating and cooling thermostat is at the normal level, if it expands at this time The liquid level of the fuel tank is lower than the low level, then this alarm is caused by the lack of oil in the system. What we need to do is to add new heat transfer oil in time until the system has a stable pressure and the liquid level of the expansion tank is at the normal level. It can be solved.
There is another situation that will also cause the fully enclosed heating and cooling thermostat to alarm for lack of refrigerant. That is, an alarm occurs after a period of use. At this time, we also need to check the liquid level of the expansion tank. If the heat transfer oil is lower than the low level, there must be a leak in the pipeline, which needs to be found and repaired in time. If it is not the leakage problem, then Most of it should be that the liquid level float switch of the expansion oil tank touches the wall of the expansion oil tank, causing the liquid level switch to not work normally. At this time, we need to remove the liquid level switch and re-reinforce it. The main reason for this situation may be due to The fully enclosed heating and cooling thermostat is caused by slight vibration during use.
The above are two solutions for the lack of refrigerant alarm. The alarm is a fully enclosed heating and cooling thermostat’s built-in protection, mainly to prevent the heating tube from burning dry, so when we encounter this problem, we can solve it in most cases according to the two methods shared by the editor. If it is solved No way to contact LNEYA after-sales technical support.
関連推奨品
-
Factors affecting cooling capacity during temperature control of battery test equipment
2303Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For ...
詳細を見る -
新エネルギー自動車バッテリー試験システムにおける冷媒の重要性
2397新エネルギー自動車バッテリー試験システムの冷媒の流量が極端に少ないと、冷媒はスロットルバルブの後端にある最初の膨張可能な空間から膨張し始める。スロットルバルブの後端のシースアップのほとんどは、スロットルバルブの後端にある。
詳細を見る -
新エネルギー自動車バッテリー試験中の温度制御
2236省エネ・排出削減政策の継続的実施に伴い、新エネルギー電力電池の開発も継続的に奨励されており、液冷システムは新エネルギー自動車にとって避けられないトレンドとなっている。液冷システム...
詳細を見る -
水冷式チラー導入の4つのポイント
2129水冷式チラーの設置は、まずチラーの設置、次に配水管の設置、配水管の洗浄、機器の断熱という4つの側面から行うことができる。水冷式冷凍機の設置工事を甘く見てはいけない。
詳細を見る
工業冷水機製造商 LNEYA Taiwan