Harm of dust to thermal oil temperature control system of reactor
Dust in daily work will also have a certain impact on the circuit board work of the thermal oil temperature control system of the reactor. Dust is an unevenly dispersed system composed of particles suspended in the air. It mainly comes from industrial emissions, combustion Soot, soil dust, etc. Let me explain what the dangers are.
1. Dust will float with the air. When it floats above the circuit board, a certain electric field will be generated when the circuit board is working. These electric fields will attract dust and make it fall on the circuit board. The dust removal of the hot oil temperature control system will cause corrosion to the printed lines in the circuit board and the metal pins of electronic components, etc., which will seriously cause the printed lines to be moldy and broken, usually the printed lines will be moldy and broken The site will occur in the thin signal line, the via hole of the multi-layer circuit board, and the impact on the circuit board after the mildew is broken is that the control fails or does not work.
2. Sometimes the metal pins of the electronic components of the thermal oil temperature control system of the reactor will be corroded, and even the metal pins will be rusted. If the component is rusted and broken, if it occurs in the power supply part, the entire circuit board will not work. If it occurs in the control part, it will cause control failure.
3. The common problem is that there is a lot of dust in the use environment, and the dust enters the heating contactor, causing the contactor to be stuck and not working. Whether it can heat up.
関連推奨品
-
バッテリー試験用冷却装置 チラー共通構成説明書
2338Under normal use, the battery test cooling device Chiller needs to be discovered in time when any part of the abnormality occurs. This requires a clear understanding of the basic configuration of the battery test cooling device Chiller. The batter...
詳細を見る -
Analysis of the work and industry application of the chiller
2015Although there are many different types of chillers, most use the same cooling principle. An important part of the process is the coolant or refrigerant, which holds more heat than water and helps maintain an efficient cooling process. Heat is rem...
詳細を見る -
極低温冷凍機の故障のヒント
1766システムの高圧と低圧が通常より高い場合、通常はシステム内に空気または過剰な冷媒があります。この場合、再度真空引きを行い、適切な量の冷媒を追加してこの問題を解決する必要がある。しかし、このような場合
詳細を見る -
[Invited to visit] CPHI CHINA 2019, Wuxi Guanya W5P22 booth is looking forward to your arrival!
2309On June 18-20, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 will re-enter Shanghai New International Expo Center. CPhI China World Pharmaceutical Raw Materials China Exhibition is an international, high-qual...
詳細を見る
工業冷水機製造商 LNEYA Taiwan