冷却と加熱のサーキュレーター装置は、ジャケット・ガラスの温度をどのように制御しているのか?
The cooling and heating circulator equipment is often equipped with a reaction kettle for temperature control, so how to connect and control the temperature?
1. Circular jacket inlet and outlet interface
We mainly use flange interfaces for the inlet and outlet of the circulating medium in the jacket glass reactor, which avoids the disadvantages of using pagoda interfaces that can easily cause resistance and affect the flow rate of the circulating medium. The high-speed flowing liquid can also form a force on the glass, which in turn forms pressure on the jacket.
2. Internal coil
The jacket glass reaction kettle refrigeration heating cycle thermostat accessory can also serve as an auxiliary heating or cooling function, without affecting the amplification of the stirring paddle, and is easy to disassemble and clean, and can be replaced for use.
3. Insulation measures
The use of the outer insulation sleeve of the jacket glass reactor body and the insulation sleeve of the circulating medium pipeline can effectively reduce the heat exchange between the equipment and the external air, thereby improving the speed of temperature rise and fall, and avoiding the selection of equipment with higher power and price.
The area of contact between the jacket glass reaction kettle and air is large, and the speed of temperature rise and fall cannot be sacrificed due to the requirement for visualization of the reaction process. Choosing an outer insulation jacket with a visible window can solve this contradiction
When the jacket glass reaction kettle adopts a three-layer design, the outer jacket is vacuumed and sealed to form a vacuum interlayer, which has a good reaction and insulation effect. Moreover, at low temperatures, there is no water mist or frost on the surface of the outer glass, and the reaction is clearly visible; When the outer glass surface is not hot at high temperatures, it can avoid the risk of scalding.
関連推奨品
-
コールドプレートフリーザーの利点
1886凍結方式は、主にスマートフォンやタブレットPCの静電容量式液晶タッチパネルに、気泡、異物、黒点、白点、位置ずれなどの製造上の欠陥があり、リ...
詳細を見る -
熱媒油循環システムの冷却性能低下の問題を解決するには?
2067一部の熱伝導オイル循環システムは、3ヶ月使用すると以前のようにはいかなくなります。この時点で、専門のアフターセールス部門に連絡し、ユーザーの電源と機器が正常かどうかを確認することをお勧めします。
詳細を見る -
適切な低温フリーザーを購入する際に注意すべきことは?
1822Fresh keeping Although the low temp freezer is not simply a "food freezer", the core function is still fresh-keeping. For example, in order to keep tuna fresh, it is necessary to have a constant temperature and strong "freezing force" inside the u...
詳細を見る -
工業用グレードの冷暖房システム配置の注意
2270産業用冷暖房システム 電源を入れる前に、銘板に指定されている電圧が家庭用電圧と同じかどうかを確認する。同様に、電源ラインを別に手配し、専用のソケットを ...
詳細を見る