How to Choose Water Chiller Units in Small Factories
Professional water chiller factory said that the quality of equipment can be seen from the three main components of 小型冷水機. The most important one is the compressor, which is the heart of the unit and the most critical component. A good compressor should not only run stably, but also ensure good energy efficiency.
Evaporator and condenser are also one of the main components of water chiller. Evaporator and condenser play the role of heat absorption and exothermic respectively. Adequate and appropriate heat transfer can give full play to the efficiency of compressor. If the heat transfer capacity of the condenser is insufficient, it will directly affect the refrigeration effect of the unit. In summer, the high pressure is easy to occur, and even the protection shutdown of the chiller is caused by the high pressure exceeding the standard. The heat transfer of evaporator is more important. The insufficient heat transfer will not only cause the inefficiency of the unit, but also make the refrigerant unable to evaporate completely. It will directly return to the compressor to cause liquid hammer and damage the compressor, thus making the whole chiller unusable.
Another main component is the expansion valve, which is not only a flow regulating valve but also a throttle valve in refrigeration equipment in the refrigeration system of water cooler. The main function is to reduce the pressure and throttle the refrigerant liquid flowing through the thermodynamic expansion valve at high pressure and normal temperature, and to change it into low temperature and low pressure refrigerant wet vapor, which enters the evaporator and vaporizes and absorbs heat in the evaporator, so as to achieve the purpose of refrigeration and cooling.
Small factories should pay attention to the following three points when choosing and purchasing:
1. Selection of key parts for chillers.
Compressor is the main index affecting the performance of shadow water chiller. In order to control the overall production cost, many water chiller manufacturers adopt poor quality products in compressor and other major parts, and even use retrofitted compressors, which seriously affects the later use efficiency of industrial water chillers, resulting in increasing energy consumption.
2. Controlling the purchase cost.
On the premise of guaranteeing chiller’s main energy, it can achieve the goal of reducing cost and satisfying enterprise’s production demand with the least capital by purchasing industrial chiller products at a higher cost performance ratio.
3. Purchase chillers according to the environment used by enterprises.
Water quality and air quality have a certain impact on the operation of water chillers. It is necessary to inform the water quality and air quality of the position of the water chiller manufacturer’s own enterprise in advance.
関連推奨品
-
電気自動車用バッテリーの作動温度試験
2011電気自動車用パワーバッテリーの通常の作動温度範囲は-30~52℃、作動温度範囲は-46~66℃であり、既存のパワーバッテリーでは達成が難しい。局所的な温暖化対策は可能であるが、このような温度範囲は、既存のパワーバッテリーでは実現が困難である。
詳細を見る -
原子炉の冷却および加熱システムの操作説明書
2129原子炉冷熱切替一体型装置は、様々な産業分野で応用されている冷却・加熱温度制御装置です。原子炉冷温切替一体型機についてどのくらいご存知ですか?製薬、...
詳細を見る -
理化学機器用特殊冷凍装置の定期メンテナンスポイント
2255実験器具専用の産業用冷凍装置は、製薬業界や化学業界で多く使用されており、使用時には注意が必要です。実験器具専用の産業用冷凍ユニットの日常的なメンテナンスは、実験器具の寿命を延ばすために欠かせません。
詳細を見る -
化学冷凍・加熱循環システム使用上の注意事項
1896化学薬品製造では、反応により熱が発生し、熱ムラが生じます。排出が間に合わないと、釜の温度が上昇して危険な状態になる。既存の原子炉の加熱システムは、熱のムラが発生しやすい。
詳細を見る
工業冷水機製造商 LNEYA Taiwan