小型高温および低温衝撃試験チャンバー容積選択手順書
When the test product (components, components, components or complete machine) is placed in a small high and low temperature impact test chamber for testing, in order to ensure that the atmosphere around the test product can meet the environmental test conditions specified in the test specification, the small high and low temperature impact test There should be some points of attention between the working size of the box and the outer dimensions of the tested product. The volume of the tested product should not exceed (20~35)% of the effective working space of the test box. It is recommended to use no more than 10% for products that generate heat during the test. The ratio of the windward cross-sectional area of the test product to the total area of the test chamber on the section is not more than (35 to 50)%. The distance of the outer surface of the test product from the wall of the test chamber is at least 100 to 150 mm.
After the test piece is placed in the box, the smooth passage is occupied, and the narrowing of the passage will result in an increase in the flow rate of the air flow. Accelerate the heat exchange between the gas stream and the test piece. This is inconsistent with the reproduction of environmental conditions, because in the relevant standards, the temperature flow around the test specimens in the test chamber should not exceed 1.7 m/s, so as to prevent the test specimens and the surrounding atmosphere from being produced. Heat transfer. If the volume of the test piece or the wind-breaking area is increased without restriction in the test, the airflow speed will increase beyond the wind speed specified in the test standard during the actual test, and the validity of the test results will be suspected.
The accuracy index of the environmental parameters in the working chamber of the small high and low temperature impact test chamber is the result of the test under no-load condition. Once the test piece is placed, the uniformity of the environmental parameters in the working chamber of the test box will be affected. The greater the space occupied, the more serious this effect will be.
According to the principle of heat conduction, the temperature of the gas flow near the tank wall is usually 2 to 3 °C from the center temperature of the flow field, and may reach 5 °C at the upper and lower limits of the high and low temperature. The temperature of the tank wall is different from the temperature of the flow field near the tank wall by 2~3 °C (depending on the structure and material of the tank wall). The greater the difference between the test temperature and the external atmospheric environment, the greater the above temperature difference, therefore, the distance from the tank wall The space within the distance (100 to 150 mm) is an unusable space.
The volume selection instructions above the small high and low temperature impact test chamber do not know that you understand it. I believe that users can better select the equipment after reading these.
関連推奨品
-
Recrystallization temperature and influencing factors?
1710Recrystallization is the process of recrystallizing crystals from a solution or melt after they are dissolved in a solvent or melted. Recrystallization can purify impure substances or separate mixed salts from each other. Among them it is the r...
詳細を見る -
低温チャンバーのメンテナンスで注意すべきこと
17982.低温チャンバーの温度と湿度は、装置の性能に影響を与える重要な要因である。機械部品の腐食を引き起こし、金属鏡の平滑性を低下させ、誤差や性能を低下させます。
詳細を見る -
What are the applications of steam circulators in chemical industry?
1902The steam circulator in the chemical industry is a temperature control equipment in the pharmaceutical and chemical industry. When users operate, they need to understand the performance and maintenance knowledge in order to operate the equipment e...
詳細を見る -
なぜ冷却水循環装置は水循環が中心なのですか?
1719冷却水循環装置は、水を冷却に利用する方法である。外気温の上昇に伴い、多くの企業でも循環水の利用が増えている。循環水の補助は、水冷を目的とした...
詳細を見る
工業冷水機製造商 LNEYA Taiwan