冷暖房用サーキュレーターの日常メンテナンス方法
After the heating and cooling circulator has been running for a long time, certain maintenance work needs to be carried out, so what should be paid attention to?
To ensure the normal operation of the heating and cooling circulator after it is started, it must be ensured that the condenser has good heat dissipation, otherwise the heating and cooling circulator group’s high-pressure protection device will act and stop due to the excessively high condensation temperature and corresponding condensation pressure, or even cause failure. The cold water in the evaporator should circulate, otherwise it will stop because the cold water temperature is too low, causing the cold water temperature protection device to act, or because the evaporation temperature and the corresponding evaporation pressure are too low, the low pressure protection device of the heating and cooling circulator acts and it stops. It even causes the cold water in the evaporator to freeze and damage the equipment.

In order to ensure the good performance of the heating and cooling circulator, please keep the chiller in a good environment with good ventilation and low temperature. Turn off the compressor first, then turn off the cooling fan. When heating and cooling the circulator every 6 months or when the performance of the chiller declines, please clean the condenser and check that the operating valve is in a normal state. The better working pressure of the condenser of the heating and cooling circulator should be lower than 1.5MPa. Frequent inspection and cleaning of the condenser can keep the performance of the machine. For air-cooled machines, please ensure that the machine is well ventilated and maintain the condenser regularly. If it is not used for a long time, sometimes the pump impeller will be blocked by sediment, so turn the pump cooling fan by hand before using the machine.
During the operation of the heating and cooling circulator unit, the parameters should be recorded in a timely and correct manner. If the heating and cooling circulator unit is in operation, if there is an alarm and shutdown, the relevant personnel should be notified in time to inspect the unit. If the fault cannot be eliminated, you can directly contact the manufacturer. It is strictly forbidden to short-circuit the water flow switch during the operation of the heating and cooling circulator unit to avoid freezing and breaking the water pipe. The heating and cooling circulator room should be equipped with corresponding safety equipment and maintenance and testing tools, such as pressure gauges, thermometers, etc., and the tools should be stored in a fixed place. Location. After the heating and cooling circulator unit is shut down, do not turn off the main power supply. If the unit is in a long-term shutdown state, all the accumulated water in the wind part of the chilled water system should be drained to prevent rust. The end cap of the water chamber should be sealed. When the heating and cooling circulator unit is shut down for a long time, maintenance work should be done.
It is recommended that the heating and cooling circulator be replaced every four years or when the quality of the lubricating oil deteriorates, impurities and moisture in the oil increase, and the condenser should be cleaned at least once a year. It is recommended to clean it once a year before use and once in a hot summer.
関連推奨品
-
半導体ウェハー温度制御における冷凍原理の説明
2416半導体ウェハー温度制御冷凍システムの運転では、ある作動流体の状態遷移を利用し、温度の低い熱源から必要な熱Q0を取り出し、熱Qkを...
詳細を見る -
マイナス30℃の低温管理機器の日常点検の注意点
1901マイナス30℃の低温制御機器は冷凍機、あるいは冷凍ユニットとも呼ばれる。冷凍機との違いは温度範囲である。産業界でよく使われる低温装置である。
詳細を見る -
Why choose LNEYA’s reactor automatic temperature control equipment?
2440With the rapid development of pharmaceutical and chemical industry, the market demand for automatic temperature control equipment for reactors is expanding. The requirements for automatic temperature control equipment for reactors are also rising,...
詳細を見る -
空冷チラー化学反応釜冷凍装置のトラブルシューティング方法
1867もし化学反応釜の空冷チラー冷凍機系統に空気が入ると、影響は多い。まず空気循環システムに入って、圧力が上昇して、凝縮器の放熱効果も......