What aspects should be paid attention to when using laboratory cryogenic refrigeration circulators?
The compact circulating cooler is an economic model for routine laboratory applications. The instrument is cooled in the temperature range of -10 or 0°C to +40°C, and the temperature control accuracy can reach ±0.5°C. It is a good way to replace expensive tap water and is an ideal choice for basic cooling tasks. The lower acquisition cost means they can recover the cost in a short time.
The device has its own self-diagnostic function, and there are liquid inlet and outlet ports and switches on the back, and the filling port is located in the top groove, which is easy to operate. Another advantage is that the ventilation slots are located at the front and back, so the device can be placed directly in another location (saving space). It can be combined with rotary evaporators, glass reactors and other instruments to carry out various chemical reactions.
If the laboratory’s small low-temperature refrigeration circulator is faulty, its operating data must be abnormal during the operation of the equipment. By checking the abnormal data, it can be judged whether it is in a faulty operating state. Companies can find and quickly and effectively deal with various common faults in a timely manner, so the cost of long-term operation of the laboratory small cryogenic refrigeration circulator is very low.
Precautions during use: In the process of operating the small low-temperature refrigeration circulator in the laboratory, it is necessary for the company to regularly conduct certain tests on the equipment. Careful statistics of various operating data can determine whether the operating status of the equipment is stable, and a suitable operating plan can be adjusted in time to prevent more failures, thereby creating conditions for extending the service life of the equipment and reducing costs. low.
関連推奨品
-
冷却と加熱のサーキュレーター装置は、ジャケット・ガラスの温度をどのように制御しているのか?
1704冷却と加熱の循環装置は、温度制御のための反応釜を装備していることが多いので、どのように接続し、温度を制御するのですか?1.1.円形ジャケットの入口と出口のインターフェース 私たちは主にフランジインターフェースを使用します。
詳細を見る -
燃料電池車が低温でコールドスタートした場合、バッテリーにどのような影響がありますか?
2015At present, the topic of fuel cell vehicles in China is relatively hot. Fuel cell vehicles have the advantages of large market space, high technological status, short hydrogenation time, high battery life, and low pollution. However, at present, f...
詳細を見る -
グリコールチラーの動作原理
2038For the low-temperature chiller using ethylene glycol solution, we call it glycol chiller. Its outlet water temperature is generally below - 10 ℃, and the specific temperature requirements shall be subject to the needs of users. Glycol chillers a...
詳細を見る -
超低温ベアリング冷却装置 シュリンクフィットベアリングとブッシングとピン
2656冶金業界では、精密工作機械の油圧システムは、工作機械が正常に動作できるように油膜粘度を安定させるために油温を制御するために冷凍機を使用する必要があります。鉄鋼製品に適用する場合、...
詳細を見る
工業冷水機製造商 LNEYA Taiwan