Motor test chiller compressor causes wear
Motor testing chiller oil quality may be one of the main reasons affecting crankshaft wear. If the engine oil is used in the chiller refrigeration system, the engine oil that does not meet the requirements and is of poor quality may cause crankshaft wear. High-speed multi-cylinder compressors have high requirements for the quality and lubrication performance of the motor test chiller oil due to high speed, high load and high exhaust gas temperature.
Motor test chiller refrigeration compressor oil selection in addition to the choice of compressor type, but also according to the type of refrigerant used in the refrigeration system, commonly used ammonia, R23 and R22 and R404a, etc., taking into account the motor Test the chiller operating conditions (such as exhaust temperature, pressure, etc.) of the refrigeration system when different refrigerants are used, all of which will affect the lubrication conditions of the refrigeration oil, so the choice of motor to test the chiller oil must consider the refrigerant used, This is related to the mutual solubility of the refrigerant, high and low temperature performance, no water content, and high chemical inertness with the refrigerant.
If the viscosity of the oil is too low and the lubricating oil is not clean, the motor will test the chiller crankshaft for abnormal wear and damage. Therefore, the refrigerating machine oil of suitable quality and suitable viscosity grade must be selected in strict accordance with the technical specifications of the motor test chiller compressor. In addition, in the process of using the motor to test the chiller, it is necessary to strengthen the cleaning of the lubrication system, clean the compressor regularly, and replace the new oil to ensure that the crankshaft of the compressor is always in a good lubrication state.
Motor test chiller operation often occurs in the wet stroke, the compressor wet stroke is the liquid into the crankcase, mixed with the frozen oil and foam. The lubrication effect of the friction parts of the motor test chiller is reduced to increase the wear. The use of high-efficiency oil separators and adjustment of refrigeration conditions can effectively prevent the wet stroke phenomenon of the refrigeration system.
The motor test chiller crankshaft upper axle and connecting rod bushings are mostly made of babbitt. Motor testing of impurities or wear metal particles in the chiller alloy can cause increased crankshaft wear if embedded in the metal layer. Therefore, the motor test chiller should use high quality bearing pads or periodically replace the bearing pads to prevent or slow the crankshaft wear.
The motor test chiller runs more in the new energy vehicle motor test, so it needs specific attention to its operating state to ensure efficient operation.
関連推奨品
-
低温チラーシステムにおける電子膨張弁の使用について
2201低温チラーシステムにおいて、電子膨張弁は、コンプレッサー、コンデンサー、エバポレーター、水冷式スクリュー冷凍機、空冷式スクリュー冷凍機...と協力して、システムの運転動力を制御する上で重要な役割を果たす。
詳細を見る -
20度工業用極低温冷凍機の運転のいくつかの要素
2345-20度工業用極低温冷凍機は、低温の冷水を供給する冷凍装置です。化学会社、製薬会社、その他の生産工程などの生産企業でよく使用されます。
詳細を見る -
工業用冷水機の分類と用途
2236In lots of industrial production processes, it is difficult to obtain high efficient industrial production efficiency if there is no industrial water chiller to provide a low temperature production environment. Therefore, industrial water chil...
詳細を見る -
What are the maintenance of glycol chillers in daily operation?
2148In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance. Refrig...
詳細を見る
工業冷水機製造商 LNEYA Taiwan