新エネルギー試験用特殊冷凍機の設置に関する注意事項
The installation of the special chiller for new energy testing is an important link before operation. The quality of the installation is directly related to the operation and operation status of the special chiller for new energy testing. So, what should be paid attention to in the installation of the special chiller for new energy testing?
If the special chiller for new energy test adopts semi-hermetic or fully-hermetic compressor, an oil separator should be installed, and an appropriate amount of oil should be added to the installed oil separator. When the evaporation temperature is lower than -15 degrees, a gas-liquid should be installed. Separator and add appropriate amount of refrigeration oil. Secondly, the compressor base should be installed with a shock-absorbing rubber seat, and the installation of the special chiller for new energy testing should leave a maintenance space to facilitate the observation of the adjustment of instruments and valves.
The high pressure gauge of the special chiller for new energy testing should be installed at the tee of the liquid storage and filling valve. The overall layout of the special chiller for new energy testing is reasonable and the color is the same. The installation structure of each type of unit should be consistent.
When debugging the special chiller for new energy test, it is necessary to pay attention to measuring the power supply voltage, measuring the resistance value of the three windings of the compressor and the insulation of the motor, checking the opening and closing of each valve of the refrigeration system, and pouring the refrigerant into the storage liquid to the standard charge after evacuation. 70%-80% of the filling volume, and then run the compressor, add air from low pressure to enough volume.
After the special chiller for new energy test is turned on, first listen to whether the sound of the compressor is normal, check whether the condenser and air cooler are running normally, and whether the three-phase current of the compressor is stable. After the special chiller for new energy test cools down smoothly, check the exhaust pressure, suction pressure, exhaust temperature, suction temperature, motor temperature, crankcase temperature, and expansion valve temperature in the refrigeration system, and observe the frosting of the evaporator and expansion valve. , observe the oil level and color change of the oil glass. Check whether the sound of the special chiller for new energy testing is abnormal.
Another point is that the special chiller for new energy testing needs to pay more attention to its maintenance knowledge and carry out a lot of related maintenance work.
関連推奨品
-
Leakage Detection Tips of Low Temperature Freezer
2189Pressure leaking detection It is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The l...
詳細を見る -
水冷式チラーと空冷式チラーの選択方法
2038現在、工業用冷水機は、石油化学工業、プラスチック工業、電子工業、真空コーティングなど、さまざまな産業に応用されている。しかし、工業用冷水機を購入する際、多くのエンタ...
詳細を見る -
20度工業用極低温冷凍機の運転のいくつかの要素
2345-20度工業用極低温冷凍機は、低温の冷水を供給する冷凍装置です。化学会社、製薬会社、その他の生産工程などの生産企業でよく使用されます。
詳細を見る -
超低温冷凍サーキュレーターのメンテナンスのポイント
1975超低温冷凍サーキュレーターは、長期間運転するとメンテナンスが必要になりますが、どのような点に注意すればよいのでしょうか。超低温冷凍サーキュレーターの点検とメンテナンスは定期的に行ってください。それは問題を見つけることができます...
詳細を見る
工業冷水機製造商 LNEYA Taiwan