反応釜の硝酸冷却システムで注意すべきことは?
After purchasing the nitric acid cooling system of the reactor, many users often do not notice the details that need to be paid attention to when the equipment is turned on. It is necessary to check whether there are few pieces of the product, whether it is damaged or not, and whether it can be used normally is the same, and what details need to be paid attention to when starting up.
The operating principle of the reaction kettle nitric acid cooling system is to convert electrical energy into heat energy to heat the materials to be heated. During operation, the low-temperature fluid medium enters its input port through the pipeline under the action of pressure, along the specific heat exchange flow channel inside the electric heating container, and uses the path designed by the principle of fluid thermodynamics to take away the high-temperature heat energy generated by the electric heating element. The temperature of the heated medium is increased, and the high temperature medium required by the process is obtained from the outlet of the electric heater.
1. Check whether the packaging is damaged and whether the anti-fall mark on the packaging box is normal; check the type and quantity according to the content in the “Packing List”.
2. Please be careful not to damage the test box when unpacking, and also need to remove the pad at the bottom of the compressor.
3. After the nitric acid cooling system of the reactor is placed in the position, adjust the level, and reserve at least a certain distance for maintenance.
4. Open the electrical control cabinet to check whether the terminals of the components are loose; whether the water box of the waterway is damaged, whether the fixing screws are loose, and then connect the power line and grounding line after checking.
5. Connect a water pipe to the water outlet joint of the nitric acid cooling system of the reactor. The length of a single water pipe should not exceed 1 meter, and the outlet of the water pipe should be extended into the floor drain. If there is no floor drain, a water receiving box can be placed directly under the joint.
6. The heat pipe of the nitric acid cooling system of the reaction kettle dissipates heat. If there is no fluidity of water suddenly at the time of high-speed operation, a lot of heat cannot be evaporated immediately, resulting in a very fast temperature rise. When the temperature exceeds the high temperature zero point, the device will maintain itself according to the shutdown method.
The above points are the details that need to be paid attention to when starting the nitric acid cooling system of the reactor. This cooling system is used to control the temperature of the material, and LNEYA’s temperature control equipment can also be used to control the process temperature of the container at the same time. For details, please contact us at sales@lneya.com
関連推奨品
-
Common faults of plate heat exchangers in new energy vehicle inspection
2580The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
詳細を見る -
原子炉の自動温度制御システムの不具合を解決するには?
2154原子炉の自動温度制御システムの性能は非常に重要です。起動できないような故障に遭遇したら、できるだけ早くそれを解決しなければならない。
詳細を見る -
どのような観点から循環式クーラーの使用を検討すべきか?
1676Circulating coolers are a popular choice for temperature-critical applications because they provide stable temperature control, constant flow and constant pressure control. Many process heating systems require cooling and heating. For example, man...
詳細を見る -
研究室用温度冷凍暖房サイクルシステム操作説明書
1897製薬・化学業界の幅広い応用に伴い、実験室温度冷凍加熱サイクルシステムは、製薬・化学業界において、一般的な温度制御機器を支えるものとして一定の地位を占めている。
詳細を見る
工業冷水機製造商 LNEYA Taiwan