The influence of the evaporator of the semiconductor thermostat on the refrigeration effect
Different models of semiconductor thermostat equipment have different options for evaporation.
According to different models, the choice of evaporator is different. For example, box-type semiconductor thermostat equipment uses water tank coil type evaporator; open semiconductor thermostat equipment and screw type semiconductor thermostat equipment use shell-and-tube evaporator ; For acid and alkali resistant semiconductor thermostat equipment, titanium tube evaporator or stainless steel plate exchanger can be selected. A kind of ice water machine, there are many choices, of course, can also be customized according to user needs.
The factors affecting the evaporation temperature of industrial semiconductor thermostat equipment are as follows:
There is oil in the evaporator pipeline. Under normal circumstances, because the lubricating oil and the refrigerant are mutually soluble, no oil film will be formed on the surface of the heat exchanger. The thermal resistance of the oil film may not be considered, but in the case of additional lubricating oil, the same label as the original one must be selected Lubricating oil to prevent the production of oil film.
The air filter is blocked, and the filter must be replaced regularly to ensure the circulating air volume required by the air conditioner. Dry filter clogged: In order to ensure the normal circulation of the refrigerating agent, the refrigeration system must be kept clean and dry. If the system has impurities, the dryer filter will be clogged and the system will be difficult to supply liquid, which will affect the cooling effect. Too little refrigerant, add refrigerant.
The temperature condition of the evaporator of the semiconductor constant temperature equipment. Under normal circumstances, the outer surface of the evaporator is very cold, and the condensed water drops continuously. The temperature of the inlet and outlet air is large. In abnormal conditions, the surface of the evaporator is not too cold and there is not much dew. , Or without condensation, the sound of refrigerant flowing is very loud, and the temperature difference between the inlet and outlet air is small. The reason is that the amount of refrigerant is insufficient, or the opening degree of the expansion valve is small.
The heat exchanger quality requirements of semiconductor thermostat equipment are very high. When choosing, users can also look at the quality and brand of their heat exchangers. It is recommended to choose a better one.
関連推奨品
-
化学や医薬品の製造工程で温度管理が必要な反応は?
2095精密な温度制御は、化学品や医薬品の製造における合成/結晶化の反応プロセスにおいて重要な役割を果たします。ファインケミカルの分野では、多くの化学反応プロセスや結晶化...
詳細を見る -
Attention points for the use of laboratory chiller manufacturers’ equipment
1720実験室では、さまざまな実験器具が広く使われている。実験器具を稼働させる場合、高温低温循環装置冷凍加熱装置とは切っても切れない関係にある。何をすべきか...
詳細を見る -
TCUマルチリアクター温度制御機器の定期メンテナンス
1847TCUマルチリアクター温度制御装置は、石油、化学、電子機器、物理、化学、生物工学、物性試験、化学分析などの研究部門、大学や専門学校で広く使用されています。
詳細を見る -
低温冷却再循環チラーの利点
1729低温冷却循環式冷凍機はコンプレッサーを使用した一種の冷凍であり、循環ポンプは- 2 5℃から30℃までの温度範囲を維持するために冷たい源を提供する。冷凍再循環式チラーは、省スペースで、冷却効率を向上させます。
詳細を見る
工業冷水機製造商 LNEYA Taiwan