グリコールチラーのメンテナンス項目の概要
During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out necessary daily maintenance.
Inspection of refrigeration system of glycol chiller: generally, various problems will inevitably occur after long-term use of glycol chiller. Once there is a fault, we should carefully check the service condition of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system, and judge whether their functions are normal. We usually check them through sound and appearance. If there are problems, we suggest to replace them in time.
Refrigerant inspection of glycol chiller: regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of glycol chiller is also different. When the low-temperature chiller works normally, the high-pressure display is 11-17kg and the low-pressure display is 3-5kg.
Inspection of cooling water system of glycol chiller: check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.
System cleaning of glycol chiller: the glycol chiller shall be cleaned once a year after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good refrigeration effect.
Voltage and current inspection of glycol chiller: regularly check whether the voltage and electric flow of glycol chiller are stable and whether the compressor operates normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
Of course, there are many other details that need your attention.
関連推奨品
-
極低温冷凍機におけるクライオポンプの設置ポイント
2311クライオポンプは極低温冷凍機の構造上、必要不可欠なものです。低温冷凍庫メーカーであるLNEYA社は、クライオポンプを設置する際には、その要件に従って運転する必要があることを皆様にお伝えしています。設置の容易さ
詳細を見る -
低温冷却再循環チラーの利点
1729低温冷却循環式冷凍機はコンプレッサーを使用した一種の冷凍であり、循環ポンプは- 2 5℃から30℃までの温度範囲を維持するために冷たい源を提供する。冷凍再循環式チラーは、省スペースで、冷却効率を向上させます。
詳細を見る -
原子炉の冷凍・加熱システムの故障に対する解決策
1893原子炉冷凍・加熱システムのパイプ材質を選択する際、パイプの接続、パイプの選択、パイプの材質に注意しなければならない。パイプは冷却と加熱に関係するため、パイプの材質を選択する必要があります。
詳細を見る -
冷暖房用サーキュレーターの日常メンテナンス方法
2033After the heating and cooling circulator has been running for a long time, certain maintenance work needs to be carried out, so what should be paid attention to? To ensure the normal operation of the heating and cooling circulator after it is star...
詳細を見る