オイルバス加熱システムにおける恒温装置の重要性
The constant temperature equipment of the oil bath heating system is used for dynamic temperature control of fluid cooling and heating with heat conducting medium, which is applied to high-precision industries such as pharmaceuticals, chemicals and semiconductors, and helps customers complete temperature control of the process. It is equipped with biochemical experimental equipment such as reactors, distillation, evaporators, and Rotary evaporator to control the cooling and heating of heat conducting medium or reaction materials.
The power switch of the transformer cooling system control box for the constant temperature equipment of the oil bath heating system adopts a dual power automatic switching device. Its main function is to automatically switch between the main and backup working power supplies. When a common power supply failure occurs, it automatically switches to the backup power supply. When both power supplies are normal, the common power supply is working and the backup power supply is in standby mode.
The programmable controller (PLC) is the control of the execution part of the air cooler control device, which receives various status signals from the transformer to control the execution part.? When the transformer of the oil bath heating constant temperature system is put into operation, the main cooler is put into operation, that is, the working group cooler is running. The auxiliary cooler is controlled based on the oil surface temperature, winding temperature, load signal, etc. of the transformer, and can be started as follows.
The power of the entire system of the constant temperature equipment in the oil bath heating system is provided by the compressor. The compressor is equivalent to moving a physical object from a low potential position to a high potential position. In the system, its purpose is to compress low-temperature gas into high-temperature gas through the compressor, and then the gas exchanges heat with other media in the heat exchanger. So the quality of the compressor will directly affect the refrigeration effect of the entire oil bath heating constant temperature system.
The function of the constant temperature equipment condenser in the oil bath heating system is to cool the high-temperature and high-pressure refrigerant superheated steam discharged by the compressor into a liquid or gas-liquid mixture. The heat released by the refrigerant in the condenser is carried away by the cooling medium (water or air), and the liquid low-temperature refrigerant is easily evaporated at low pressure, converted into steam, and absorbs the heat of the cooled medium to achieve refrigeration purposes.
関連推奨品
-
グリコール・チラーの原理分析
2000Glycol chiller is an industrial chiller with glycol as refrigerant. The structure of glycol chiller is roughly the same as that of ordinary industrial chiller, which is composed of compressor, evaporator, condenser and electric control system....
詳細を見る -
超低温循環式冷凍機をより省エネにする方法
1995現代では、環境保護と省エネが開発テーマであり、工業用冷凍機も同様である。では、工業用チラーをより省エネにするにはどうすればいいのでしょうか?まず、工業用冷凍機の配管スケールを防止・低減する。
詳細を見る -
工業用SUNDI冷暖房温度制御システムの説明
2431工業用冷暖房温度制御システム「SUNDI」シリーズは、LNEYAが冷暖房・温度制御の分野で独自の優位性を活かして開発・製造した装置で、カスタマイズされたサービスを...
詳細を見る -
新エネルギー自動車とLNEYAバッテリー試験温度制御ユニットの密接な接触
2689エネルギー問題の現状と自動車産業の活況を踏まえ、新エネルギー自動車は現代の自動車産業と同様にタイムリーな存在となっている。新エネルギー車のバッテリー部分は、自動車産業の発展において決定的な役割を果たしている。
詳細を見る
工業冷水機製造商 LNEYA Taiwan