The reason why the cooling thermostat Chiller suddenly fails to start
If there are any unexpected situations during the use of the cooling thermostat Chiller, it is important to promptly identify the specific reasons before resolving them, in order to effectively address various issues. For example, what is the reason why the cooling thermostat Chiller suddenly fails to start during operation?
One、 The reason why the cooling thermostat Chiller cannot start
1. The main reason is that during the operation of the system, the pressure at the equipment inlet is low, which cannot meet the basic operating conditions, leading to the problem of not being able to start.
2. According to the instructions for the configuration of the refrigeration thermostat Chiller, it can be understood that it is mainly caused by the idle water pump and other reasons. As long as the air in each system of the refrigeration thermostat Chiller is released, it can meet the suitable operating environment and achieve the purpose of starting the refrigeration thermostat Chiller.
3. The issue of stress. After experiencing varying degrees of startup difficulties, it is necessary to complete the maintenance of the refrigeration thermostat Chiller according to actual needs.
4. To ensure smooth operation, it is necessary to effectively control the inlet and outlet of the water pump during the use of the refrigeration thermostat Chiller. As the air is continuously eliminated, any malfunctions that cannot be started can be resolved.
Two、 Handling methods for encountering high-voltage faults
1. Due to insufficient cooling water flow, the rated water flow cannot be reached. The main manifestation is that the pressure difference between the inlet and outlet water of the unit decreases and the temperature difference increases. The reason for insufficient water flow is due to a lack of water or air in the system. The solution is to install an exhaust valve at a high position in the pipeline for exhaust; If the pipeline filter is blocked or too fine, and the permeability is limited, a suitable filter should be selected and the filter screen should be cleaned regularly; The selection of water pumps is relatively small and not compatible with the system. Excessive refrigerant charge.
2. This situation usually occurs after maintenance, manifested as high suction and exhaust pressure, balance pressure, and high operating current of the compressor. It should be deflated under rated operating conditions based on suction and exhaust pressure, balance pressure, and operating current until normal, so it is still necessary to regularly check.
関連推奨品
-
化学反応発熱または吸熱温度動的補償システム
2062化学実験室、パイロットプラント、反応プロセスでは、温度制御には動的温度制御システムの使用が必要です。反応器を制御する場合、発熱反応と吸熱反応を高速で補正する必要があります。
詳細を見る -
温度要件を満たす半導体テストチラーの制御方法
2114バイオ医薬品の分野では酵素の活性や製品の生産をコントロールするために高精度の温度が要求され、化学工業の分野では化学反応を安定的に進行させるために特定の温度が要求される。
詳細を見る -
Auxiliary equipment for LNEYA glass reactor system
1406Metal jacketed glass reactor system Mechanical seal stainless steel jacket connected cylindrical glass container PTFE gasket seal top flange and stainless steel jacket; With insulation layer, the outer layer is stainless steel SUS layer; The geo...
詳細を見る -
低温チラーの製品カテゴリー
2104低温のスリラーは一種の国内産業市場の大きい要求の専門の冷凍の設計です。多くの企業は産業生産の低温の環境を作成するのに低温のスリラー プロダクトを使用する必要があります。異なったI...
詳細を見る
工業冷水機製造商 LNEYA Taiwan