What should be paid attention to when placing the thermostat system?
There are certain differences in the size and performance of the high and low temperature thermostat systems produced by different manufacturers. The user needs to pay attention to how it is placed when placing it after purchase, otherwise it will be detrimental to the operation of the high and low temperature thermostat system.
The location where the high and low temperature thermostat system is installed should consider the heat dissipation efficiency and whether it is easy to check and maintain. The floor where the equipment is placed must be flat and have sufficient strength (3.4N/m2 or higher). Choose a place where dust and vibration are less affected s position.
The high and low temperature thermostat system should be installed in a dry room, and there should be a power supply and a sewer nearby. The equipment should be installed in a place with little dust, and the wind condition will cause the refrigerant (fluorohydrocarbon) to leak from the equipment. There will be no hypoxia.
Good ventilation should be maintained around the installation of the high and low temperature thermostat system. During operation, the equipment will radiate heat. If it is an air-cooled thermal shock, it will directly emit heat through the condensing wind. When the room is small and poorly ventilated, the indoor temperature will rise rapidly, causing the machine to stop running and alarm . Secondly, the installation should be far away from flammable or explosive materials or other materials that may generate high heat.
When placing it, please be careful not to let sunlight directly shine on the equipment. When the equipment is used beyond this range, the safety device will start or the equipment will stop running. In order to obtain stable performance of the high and low temperature thermostat system, the installation room should be air-conditioned to keep the indoor temperature between 10°C and 30°C.
The atmospheric environment of the installation site of the high and low temperature thermostat system is consistent with the general indoor air-conditioned atmospheric environment. If there are organic solvents, plasticizers, acids, alkalis or other chemicals in the air, the parts or coatings of the equipment will be corroded and damaged.
The above content is the precautions when placing the high and low temperature thermostat system, which requires the operator to take it seriously and read the instruction manual in detail.
関連推奨品
-
What are the main equipment needed for industrial chillers?
1674Main equipment of industrial chiller: compressor, condenser, expansion valve, evaporator, chilled water pump, cooling water pump cooling tower (water cooling) Selection: know the required inlet and outlet water temperature, the required cooling ca...
詳細を見る -
温度衝撃試験装置の高温障害処理
2177The whole function of Wuxi Guanya LNEYA thermal shock test chamber is computer controlled. It is a self-developed software with a good operation interface, which makes the operation and monitoring of the user simpler and more intuitive. The mainte...
詳細を見る -
産業用加熱サーキュレーターはどこで役立つのか?
2231The industrial heating circulator can provide a circulation device of cold source and heat source, and has a wide working range. It is used in the pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reac...
詳細を見る -
チラーの断熱性はどの程度重要ですか?
2491回答冷凍機の場合、高温で運転すると工業用冷凍機内の冷気が大量に失われる可能性があります。使用環境の密閉効果後、タイムリーで効果的な保温を行うことで、工業用冷凍機の運転...
詳細を見る
工業冷水機製造商 LNEYA Taiwan