水冷式チラーの高圧・低圧故障の解決法
The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of water-cooled chiller. The reason can be preliminarily identified as poor water quality, and corresponding impurities (leaves, weeds, etc.) enter the water distribution hole, which affects the heat dissipation of the cooling water tower. Next, I will introduce the reasons and solutions for the high and low pressure disadvantages of a water-cooled chiller.
Causes and solutions of high and low pressure disadvantages of water-cooled chiller:
In the application of water-cooled chiller, we often encounter high and low pressure alarm of chiller! In terms of high pressure, it is generally poor heat dissipation, which will lead to poor cooling effect of the chiller. For a long time, high pressure will also lead to high current and burn out the compressor. Generally, there is no cold coal or cold coal leakage in the low pressure alarm. The compressor will also be damaged if it works at low pressure for a long time.
Generally, water-cooled chillers have high and low pressure gauges, which are divided into high pressure and low pressure. In addition, industrial chillers are roughly divided into air-cooled chillers and water-cooled chillers: at present, the surface plate of industrial chillers on the market is divided into computer board and manual control board. High pressure and low pressure of computer board are well separated, but generally, the high and low pressure alarm lights of manual control board chillers are together, so it is not so easy to distinguish.
Therefore, you should first know whether the chiller you are using is an air-cooled chiller or a water-cooled chiller, whether it is a computer board or a manual control board, whether it is a high-pressure alarm or a low-pressure alarm. For the high-pressure alarm of the air-cooled chiller, you need to clean the cooling network, and for the low-pressure alarm, you need to check whether the cold coal leaks or the pressure gauge has no pressure, The high pressure alarm of water-cooled chiller requires cleaning the condenser. Low pressure alarm also depends on whether the pressure gauge has no pressure, so it is necessary to check the leakage, make up the deficiency and add cold coal.
関連推奨品
-
反応釜のインテリジェント温度制御システムの主な危険性は何ですか?
2143反応器のインテリジェントな温度制御システムは、様々な化学罰金で使用されています。業界の安全問題が絶えず注目される中、原子炉のインテリジェント温度制御システムのいくつかの危険要因を回避する必要があります。
詳細を見る -
原子炉加熱冷却システムの主な目的
2323反応釜加熱冷却システムは、高純度金属、希少物質精製、実験室環境シミュレーション、マグネトロンスパッタリング、真空コーティングなどの産業に適しています。大型の極低温ポンプユニットは、反応釜の加熱と冷却を...
詳細を見る -
公式発表!2018年API Chinaが正式にキックオフ
1981Official announcement! 2018 API China On October 17th, the Nanjing International Expo Center officially kicked off~ Wuxi Guanya carries popular products: Refrigeration heating temperature control system, TCU, refrigeration heating circulator and o...
詳細を見る -
石油精製・脱脂のワークフローと装置構成
2023オイル脱脂プロセスは、ワックスとオイルの融点差に基づいており、温度が下がるにつれてオイルへのワックスの溶解度が小さくなり、冷却によって結晶ワックスが析出する。その後、冷却によって結晶ワックスが析出する。
詳細を見る
工業冷水機製造商 LNEYA Taiwan