遠心式冷凍機の使用前に知っておくべきこととは?
There are some differences in the use of cryogenic chillers between different compressors, but not very much of it. Due to the different styles of different compressors, the points to pay attention to during operation are also different. For example, what should we know about centrifugal cryogenic chillers before the operation?
Before we understand the centrifugal cryogenic chillers, we first learn to understand the structure of centrifugal cryogenic chiller which is mainly composed of centrifugal compressor, the main motor, compressor, evaporator, condenser, the throttle device entry’s energy regulator, smoke gas recovery unit, lubricating oil system, safety protection device and microcomputer control system.
In the horizontal tube-shell structure adopted by the evaporator and the condenser, the refrigerant of the 極低温冷凍機 flows on the side of the shell, and the upper part of the evaporator has a liquid shield to prevent the refrigerant droplets from evaporating into the compressor directly.
The throttle device of the centrifugal cryogenic chiller is to put the high-pressure refrigerant liquid stored at the bottom of the condenser into the evaporator for evaporative refrigeration.
At the same time, the lubricating oil system of centrifugal cryogenic chiller is composed of the oil pump, oil cooler, oil filter and regulating valve, etc. This system supplies oil for lubrication and cooling to the bearings of the compressor, gear shaft, main motor shaft and gear mesh surface. The centrifugal cryogenic chillers are becoming increasingly compact in structure, and their oil pumps are generally built-in and immersed in the oil tank.
In the use of centrifugal cryogenic chillers, it is necessary to pay attention to the charge and discharge of refrigerant. When the refrigerant is first charged, it is generally advisable to charge 50% ~ 60% of the rated amount, and the refrigerant can be submerged in the evaporator 13 heat transfer pipes.
This common sense of centrifugal cryogenic chiller should be understood clearly, which helps us better use the centrifugal cryogenic chiller.
関連推奨品
-
新エネルギー自動車用バッテリーの電力試験システムとは?
1951LNEYAパワーバッテリーシステムは、新エネルギー車のバッテリーテスト用にテストされているが、現代の新エネルギー車には多くの種類のバッテリーがある。では、どのような特徴があるのだろうか。三元リチウム電池とは、リチウム電池の...
詳細を見る -
ガス冷却温度制御システムの光モジュールへの応用
1872ガス冷却温度制御システムは、広い温度範囲を持っており、より多くの生産とエンジニアリング環境の要件を満たすために広く使用することができます。チップ、マイクロエレクトロニクスデバイ...
詳細を見る -
実験室/生物工学温度制御システムの使用とメンテナンス
19251.使用する前に取扱説明書をよく読み、操作の手順と重要な指示を熟知し、取扱説明書に指定された条件に従って操作してください。2.実験室/生物工学の温...
詳細を見る -
半導体温度制御装置用コントローラーの機能とは?
1487In the temperature control equipment of semiconductor components, each accessory has a different function. Due to the different functions, the function of the temperature control valve and controller of the semiconductor components of LNEYA is dif...
詳細を見る
工業冷水機製造商 LNEYA Taiwan