産業用冷暖房チラーからの騒音がある場合、どうすればよいですか?
The industrial cooling and heating temperature control equipment adopts a PID algorithm temperature control system to accurately adjust the temperature based on the detected temperature and the set temperature value, improving the drawbacks of traditional manual control of the reaction kettle.
1. The industrial cooling and heating temperature control equipment, the chiller circulating pump, converts electrical energy into mechanical energy to promote the liquid phase circulation of the heat transfer oil, and transfers heat to the reaction kettle. The heat transfer oil exchanges with the materials in the reaction kettle and then returns to the oil heater, where it is heated again under the pressure of the pump and enters the next cycle. Through repeated cycles, heat is transferred and transported, heated and cooled, or the temperature of the reactor is maintained to meet the temperature requirements required by the production process.
2. When high noise occurs during the operation of the industrial cooling and heating temperature control equipment, the chiller needs to be inspected and promptly addressed if any problems are found. The internal components of the industrial grade cold and hot temperature control thermostat are excessively worn, such as the wear and tear of the cylinder body and valve plate of the plunger pump, as well as the wear and tear of the matching parts between the plunger and the plug hole, causing serious internal leakage in the pump. When the pump outputs high-pressure and low flow oil, flow pulsation will occur, causing high noise.
3. The pump valve plate is also one of the important components that can easily cause noise. Industrial cooling, heating, and temperature control equipment. During use, the water chiller may shorten the unloading groove and change the unloading position due to surface wear or oil sludge deposition at the opening of the unloading groove, resulting in oil trapping and higher noise.
4. When air is mixed into the cold water oil of industrial cooling and heating temperature control equipment, it is easy to form cavitation phenomenon in its high-pressure zone, which spreads in the form of pressure waves, causing oil oscillation and causing cavitation noise in the system.
関連推奨品
-
電気自動車のモーターテストの結露が高すぎるのを解決するには?
2208電気自動車のモーターテストの凝縮圧力は上昇し、圧縮機能は増加し、冷却能力は低下し、冷却係数は低下し、エネルギー消費量は増加する。このような現象が発生する理由は...
詳細を見る -
LNEYA’s 300,000 kcal air-cooled unit on air tightness
2044When the user runs the 300,000 kcal air-cooling unit, it needs to check the air tightness, because the airtightness may cause the air-cooling unit to consume too much energy. In order to prevent the temperature from falling for a long time during ...
詳細を見る -
エバポレーター付きトランスミッション・パワートレイン冷却システム
1995蒸発器は、冷凍システムの4つの主要コンポーネントの1つであり、冷凍効果と効率の究極の具体化である。蒸発器は一般的に、トランスミッションのパワートレイン冷却システムによって設計され、装備されています。
詳細を見る -
原薬製造における温度サイクル制御加熱・冷却の重要性
2353中国は世界最大の原薬供給市場となっている。外資系メーカーが必要とする原薬や中間体のほとんどは、わが国で購入されている。そのほとんどの製剤製品の医薬品外注工程、製造工程...
詳細を見る
工業冷水機製造商 LNEYA Taiwan