You Must Not Know the Low Temp Freezer Technology
For freezer, everyone knows they are used to store things. However, for this operation, we do not necessarily know that I will popularize the ultra low temp freezer today.
The temperature of the ultra low temp freezer can reach minus 60 degrees Celsius. This harsh temperature can not be achieved for the all refrigerators. The working principle of cascade refrigeration is adopted in ultra-low temperature refrigeration system, and refrigeration is used in high and low temperature closed compressor. Copper tubes of low-temperature evaporators are directly attached to the outer side of the inner box in the form of coils, and are filled with thermal conductive mortar in the gap between the coils and the wall of the box to increase the heat exchange effect. The condenser evaporator is shell-and-tube structure with four-tube threaded copper tube inside, adopting counter-current heat exchange mode.
When the power supply is connected, the first stage compressor starts first when the panel display temperature is higher than the set temperature and the first stage refrigeration system starts to work, which makes the condenser temperature of the second stage refrigeration system drop, that is, the refrigerant temperature of the second stage decreases. After delay of the several minutes, the second stage refrigeration system also starts to work. Its evaporator is on the inner wall of the refrigerator, which can make the temperature of the interior refrigerator decreases a lot. The heat emitted by the condenser is absorbed by the evaporator of the first refrigeration system. The heat emitted by the first condenser is scattered in the air.
When the internal temperature of the refrigerator reaches the set temperature, the resistance of the temperature sensor transmits the information, and the control relay loses power and disconnects and the two-stage refrigeration system stops working. When the temperature in the refrigerator rises again and exceeds the set temperature, the refrigerator repeats the above operation process again, so that the temperature in the refrigerator remains at the set temperature.
Welcome to our company to buy low temp freezer.
関連推奨品
-
冷凍・暖房サイクル機器の配管詳細説明
2118When the refrigeration and heating cycle equipment is in operation, the user will find that whether or not the fully enclosed pipeline affects the overall performance. The LNEYA refrigeration and heating cycle equipment adopts a fully enclosed cyc...
詳細を見る -
グリコール・チラーの特性と用途
2090グリコールチラーは、研削盤、CNC工作機械、各種精密工作機械の冷却工程に適用され、工作機械の熱変形を効果的に低減し、工作機械の加工精度を向上させることができます。
詳細を見る -
空冷チラー化学反応釜冷凍装置のトラブルシューティング方法
1867もし化学反応釜の空冷チラー冷凍機系統に空気が入ると、影響は多い。まず空気循環システムに入って、圧力が上昇して、凝縮器の放熱効果も......
詳細を見る -
石油暖房システムの設置および故障分析
2313熱媒油暖房システム装置を設置する際、設置中にいくつかの不具合が発生しないよう、システムに注意を払う必要がある。故障が発生した場合、熱転写油加熱システムに関連する故障を理解する必要があります。
詳細を見る