{"id":2775,"date":"2024-03-19T10:49:17","date_gmt":"2024-03-19T02:49:17","guid":{"rendered":"https:\/\/www.lneya.com\/news\/commonly-used-chillers.html"},"modified":"2024-03-19T10:49:17","modified_gmt":"2024-03-19T02:49:17","slug":"commonly-used-chillers","status":"publish","type":"post","link":"https:\/\/tw.lneya.com\/ja\/news\/commonly-used-chillers.html","title":{"rendered":"Classification and advantages and disadvantages of commonly used chillers"},"content":{"rendered":"<p>\t\t\t\t\t\t<span style=\"font-family:Arial;\">What are the classification and advantages and disadvantages of chillers? Let us take a look together today.<\/p>\n<div style=\"text-align:center;\">\n\t<span style=\"font-family:Arial;\"><\/span><img decoding=\"async\" src=\"https:\/\/tw.lneya.com\/wp-content\/uploads\/2023\/05\/1-2003161033263b.jpg\" alt=\"\">\n<\/div>\n<p><\/span> <br \/><span style=\"font-family:Arial;\">1. Various classification methods of chillers<\/span><br \/><span style=\"font-family:Arial;\">1. According to condenser cooling method: water-cooled chiller and group air-cooled water chiller.<\/span><br \/><span style=\"font-family:Arial;\">2. According to the refrigerant load: water-cooled chiller, brine chiller, glycol chiller.<\/span><br \/><span style=\"font-family:Arial;\">3. According to the compressor form: piston chiller, screw chiller and centrifugal chiller.<\/span><br \/><span style=\"font-family:Arial;\">4. According to the form of energy utilization: single cold heat pump type, heat recovery type and single cold ice storage dual function type<\/span><br \/><span style=\"font-family:Arial;\">5. According to the cold water outlet temperature: air-conditioning type (7 degrees, 10 degrees, 13 degrees, 15 degrees) and low temperature type (-5 degrees to -30 degrees).<\/span><br \/><span style=\"font-family:Arial;\">6. According to the sealing method: open, semi-enclosed, and fully enclosed.<\/span><br \/><span style=\"font-family:Arial;\">7. By fuel type: oil type (diesel, heavy oil) and gas type (kerosene, natural gas).<\/span><br \/><span style=\"font-family:Arial;\">8. Different according to energy compensation: power compensation (compression type) and thermal compensation (absorption type).<\/span><br \/><span style=\"font-family:Arial;\">9. According to refrigerant: R22R123, R134a<\/span><br \/><span style=\"font-family:Arial;\">10. According to different heat sources (absorption type): hot water type, steam type, direct combustion type.<\/span><\/p>\n<p><span style=\"font-family:Arial;\">2. The advantages and disadvantages of various chillers<\/span><\/p>\n<p><span style=\"font-family:Arial;\">Piston chiller<\/span><br \/><span style=\"font-family:Arial;\">advantage:<\/span><br \/><span style=\"font-family:Arial;\">1. The material is simple, general metal materials can be used, the processing is easy, and the cost is low.<\/span><br \/><span style=\"font-family:Arial;\">2. The system device is simple, easy to lubricate, and does not require an exhaust device.<\/span><br \/><span style=\"font-family:Arial;\">3. With multiple heads, high-speed multi-cylinders, performance can be improved.<\/span><br \/><span style=\"font-family:Arial;\">Disadvantages:<\/span><br \/><span style=\"font-family:Arial;\">1. There are many spare parts, many wearing parts, complicated and frequent maintenance, and high maintenance cost.<\/span><br \/><span style=\"font-family:Arial;\">2. The compression ratio is low, and the cooling capacity of a single unit is small.<\/span><br \/><span style=\"font-family:Arial;\">3. The adjustment performance of the single machine head is poor under partial load, and the unloading adjustment can not be stepless adjustment.<\/span><br \/><span style=\"font-family:Arial;\">4. It belongs to up and down reciprocating motion, and the vibration is large.<\/span><br \/><span style=\"font-family:Arial;\">5. Large weight index per unit cooling capacity<\/span><\/p>\n<p><span style=\"font-family:Arial;\">Screw chiller<\/span><br \/><span style=\"font-family:Arial;\">advantage:<\/span><br \/><span style=\"font-family:Arial;\">1. Simple structure, few moving parts, few wearing parts, only 1\/10 of the piston type, low failure rate and long life.<\/span><br \/><span style=\"font-family:Arial;\">2. Smooth circular motion, no &#8220;surging&#8221; phenomenon during low load operation, low noise and low vibration.<\/span><br \/><span style=\"font-family:Arial;\">3. The compression ratio can be as high as 20, and the EER value is high.<\/span><br \/><span style=\"font-family:Arial;\">4. Convenient adjustment, stepless adjustment within the range of 10%~100%, high efficiency under partial load, and significant power saving.<\/span><br \/><span style=\"font-family:Arial;\">5. Small size and light weight, it can be used as a built-up fully enclosed large-capacity unit.<\/span><br \/><span style=\"font-family:Arial;\">6. Not sensitive to wet stroke.<\/span><br \/><span style=\"font-family:Arial;\">7. It belongs to positive pressure operation, and there is no problem of external air intrusion and corrosion.<\/span><br \/><span style=\"font-family:Arial;\">Disadvantages:<\/span><br \/><span style=\"font-family:Arial;\">1. The price is higher than the piston type.<\/span><br \/><span style=\"font-family:Arial;\">2. The capacity of single machine is smaller than that of centrifugal type, and the speed is lower than that of centrifugal type.<\/span><br \/><span style=\"font-family:Arial;\">3. The lubricating oil system is more complicated and consumes a lot of fuel.<\/span><br \/><span style=\"font-family:Arial;\">4. The noise of large-capacity unit is higher than that of centrifugal type.<\/span><br \/><span style=\"font-family:Arial;\">5. High processing precision and assembly precision are required.<\/span><\/p>\n<p><span style=\"font-family:Arial;\">Modular chiller<\/span><br \/><span style=\"font-family:Arial;\">advantage:<\/span><br \/><span style=\"font-family:Arial;\">1. It is an improved type of piston chiller and screw chiller. It is composed of multiple chillers.<\/span><br \/><span style=\"font-family:Arial;\">2. The unit is small in size, light in weight, low in height and small in area.<\/span><br \/><span style=\"font-family:Arial;\">3. Simple installation, no need to reserve installation holes, convenient on-site assembly, especially suitable for renovation projects.<\/span><br \/><span style=\"font-family:Arial;\">Disadvantages:<\/span><br \/><span style=\"font-family:Arial;\">1. The price is more expensive.<\/span><br \/><span style=\"font-family:Arial;\">2. The number of modules should not exceed 8 in general.<\/span><\/p>\n<p><span style=\"font-family:Arial;\">Water source heat pump unit<\/span><br \/><span style=\"font-family:Arial;\">advantage:<\/span><br \/><span style=\"font-family:Arial;\">1. Save energy and recover heat when running in winter.<\/span><br \/><span style=\"font-family:Arial;\">2. There is no need for refrigerating machine room, no big ventilation ducts and circulating water pipes, and no heat preservation, reducing the cost.<\/span><br \/><span style=\"font-family:Arial;\">3. Easy to measure.<\/span><br \/><span style=\"font-family:Arial;\">4. Convenient installation and low maintenance cost.<\/span><br \/><span style=\"font-family:Arial;\">5. Flexible application and convenient adjustment.<\/span><br \/><span style=\"font-family:Arial;\">Disadvantages:<\/span><br \/><span style=\"font-family:Arial;\">1. The fresh air cannot be used to the fullest extent during the transition season.<\/span><br \/><span style=\"font-family:Arial;\">2. The unit is noisy.<\/span><br \/><span style=\"font-family:Arial;\">3. Most of the units are installed in the ceiling, which brings a certain degree of difficulty to maintenance<\/span><\/p>\n<p><span style=\"font-family:Arial;\"><strong>T<\/strong><strong>o Sum Up<\/strong><\/span><br \/><span style=\"font-family:Arial;\">In summary, we gave a detailed introduction to the types of chillers and the advantages and disadvantages of each type. LNEYA specializes in the development and production of cooling water circulators. The temperature of the heat transfer liquid can be adjusted. It adopts international brand accessories and has stable performance.<\/p>\n<p><\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>What are the classification and advantages and disadvantages of chillers? Let us take a look together today. 1. Various classification methods of chillers1. According to condenser cooling method: water-cooled chiller and group air-cooled water chiller.2. According to the refrigerant load: water-cooled chiller, brine chiller, glycol chiller.3. According to the compressor form: piston chiller, screw chiller and centrifugal chiller.4. According to the form of energy utilization: single cold heat pump type, heat recovery type and single cold ice storage dual function type5. According to the cold water outlet temperature: air-conditioning type (7 degrees, 10 degrees, 13 degrees, 15 degrees) and low temperature type (-5 degrees to -30 degrees).6. According to the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[44],"tags":[],"class_list":["post-2775","post","type-post","status-publish","format-standard","hentry","category-news"],"metadata":{"views":["2286"],"_wp_old_date":["2023-05-17"],"_edit_last":["1"],"rank_math_og_content_image":["a:2:{s:5:\"check\";s:32:\"533867b3deb74dd25683d6b6dd6e49fb\";s:6:\"images\";a:1:{i:0;i:2776;}}"]},"taxonomy_info":{"category":[{"value":44,"label":"NEWS"}]},"featured_image_src_large":false,"author_info":{"display_name":"lneyaadmindy","author_link":"https:\/\/tw.lneya.com\/ja\/author\/lneyaadmindy"},"comment_info":0,"category_info":[{"term_id":44,"name":"NEWS","slug":"news","term_group":0,"term_taxonomy_id":44,"taxonomy":"category","description":"","parent":0,"count":803,"filter":"raw","cat_ID":44,"category_count":803,"category_description":"","cat_name":"NEWS","category_nicename":"news","category_parent":0}],"tag_info":false,"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/posts\/2775","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/comments?post=2775"}],"version-history":[{"count":0,"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/posts\/2775\/revisions"}],"wp:attachment":[{"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/media?parent=2775"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/categories?post=2775"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tw.lneya.com\/ja\/wp-json\/wp\/v2\/tags?post=2775"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}