Characteristic Analysis of Industrial Air Cooled Chiller
Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be considered. Since the heat exchange source of air-cooled chiller is air and equipped with special fan, it is called “air-cooled chiller”. It is widely used in medical, biological, chemical, laser, metallurgy, equipment manufacturing, electroplating, plastic processing and other industries.
Working principle of air-cooled industrial chiller: different from the traditional water-cooled chiller, the air-cooled chiller does not need the cooling capacity brought by the cooling tower, so it avoids more investment, and is easy to install and manage. Casters are equipped at the bottom of the chiller, which can be moved to cycle between different working areas. This saves a lot of unnecessary fixed investment, and cold water can be discharged directly by connecting power supply and water pipe. According to the design requirements, the outlet water temperature is generally 2 ℃, 0 ℃, -5 ℃ and -15 ℃. When the temperature is below zero, the refrigerant needs to be mixed for heat exchange. The commonly used refrigerant is ethylene glycol.
Similar to the conventional chiller, the air-cooled chiller also has a fixed refrigeration cycle route. The principle is to use the inverse Carnot effect, which is similar to the current household air conditioner, but the system structure of the refrigeration loop is improved, so the cop (energy efficiency ratio) is often very high.
Characteristics of industrial air-cooled chiller:
1. All pipelines are of thermal insulation design to prevent local convection of machine pipelines.
2. Cooling temperature range: 5 ℃ ~ 35 ℃.
3. The independent temperature controller has anti freezing protection.
4. Stainless steel insulated water tank.
5. Control line phase sequence protection and high and low voltage switch control of refrigerant system.
6. Hydrophilic optical fin condenser has better heat transfer effect and faster heat dissipation.
7. The compressor and pump are provided with overload protection.
8. The shell and tube evaporator with large capacity is adopted, which has good refrigeration effect and can be applied to the environment with high temperature.
9. R404A refrigerant is used, with good refrigeration effect.
10. R507C environment-friendly refrigerant is optional.
Recomendaciones relacionadas
-
Test of working temperature of electric vehicle power battery
2011The normal working temperature range of power batteries for electric vehicles is -30 ~ 52 ° C, and the working temperature range is -46 ~ 66 ° C, which is difficult to achieve with existing power batteries. Although local warming measures can be u...
Ver detalles -
¿Cómo mantener el sistema de refrigeración de alta y baja temperatura a temperatura constante?
1880El sistema de refrigeración de alta y baja temperatura a temperatura constante realiza operaciones de refrigeración y calefacción en la industria farmacéutica y química. Sigue las normas de funcionamiento y requisitos meticulosos para mejorar continuamente su qu...
Ver detalles -
Refrigeración Cerrada Calefacción Circulador Manual de Mantenimiento Diario
2637Las circuladoras cerradas de refrigeración y calefacción de diferentes fabricantes tienen una determinada vida útil. Un funcionamiento y un mantenimiento razonables y correctos de los termostatos cerrados de refrigeración y calefacción pueden prolongar eficazmente su vida útil.
Ver detalles -
Integrated control system high and low temperature cycle device ZLF series use items
2048With the development of society, the chemical industry has been further developed, and the temperature system control of the reactor has been strengthened, so as to ensure that the monitoring environment is in a good state, to ensure that the temp...
Ver detalles
工業冷水機製造商 LNEYA Taiwan