Precautions for chiller cooling system in low temperature operation test
There are certain differences in the use method, function, structure, etc. of different types of chiller cooling systems for low-temperature operation test.
The chiller of the industrial low-temperature operation test requires heat to be generated during operation. The cooling air should be circulated. There should be a certain space around the installation, and the generated heat should be dissipated upwards, so do not install it around equipment that is not heat-resistant. The chiller of the industrial low-temperature operation test cooling system should be installed directly on the horizontal surface. Do not install it upside down, diagonally or vertically.
The chiller cooling system for industrial low-temperature operation test cannot be installed in places where there are various fibers, paper (chips), metal fragments, etc. The water outlet of the chiller cooling system for industrial low-temperature operation test should be connected with the water inlet of your instrument, and the water outlet of the instrument should be connected with the water inlet of the cooling circulating water machine.
Check whether the air filter, heat exchanger coils and fins of the air-cooled low-temperature operation test cooling system chiller are too dusty. Is the air inlet and outlet dredged? Is the fan and fan blade working normally? Is the wind power normal? Is the water system normal?
Check if the chiller water system of the air-cooled low-temperature operation test cooling system is leaking. Is the water inlet and outlet dredged? Is the pump working normally? Listen to the power on and listen to the air-cooled low-temperature operation test cooling system chiller compressor working sound is normal, whether there is abnormal sound, whether the electric fan, water pump is noisy, whether the noise is too loud, etc. The chiller of the air-cooled low-temperature operation test cooling system is in operation, and under normal conditions, the oscillation is slight and the noise is small.
Check the air-cooled low-temperature operation test cooling system chiller refrigeration system for cracks, damage, frost and condensation and other conditions in the pipes. Whether there is friction between the chiller refrigeration pipes of the air-cooled low-temperature operation test cooling system, the pipes and the shell, etc., especially the welding place of the refrigerant pipe, and whether there is the connection of the chiller joint of the air-cooled low-temperature operation test cooling system Leakage, as long as there is a leak, there will be oil stains. You can also use a clean soft cloth or soft paper to scrub the welded joints and joints of the pipeline, and investigate whether there is any oil stains to determine whether there is a leak.
Check whether the electrical system fuse of the air-cooled low-temperature operation test cooling system chiller is blown, whether the insulation of the electrical wire is intact, whether the circuit board is cracked, whether the connection is loose, etc. Especially if the electrical connection is excellent in touch, the wiring screws and connectors are easy to loose and cause poor touch.
Recomendaciones relacionadas
-
¿El equipo de control de temperatura para pruebas de componentes semiconductores es un refrigerador?
1627El equipo de control de temperatura para pruebas de componentes semiconductores se utiliza en la prueba de simulación del rendimiento de temperatura de semiconductores, chips y otros componentes, y realiza pruebas de temperatura en diferentes rangos de temperatura dentro de la ra...
Ver detalles -
Selection and installation of the expansion valve for recirculating chillers
1933Regarding today's topic, we have the following analysis. The selection of expansion valve plays an important role in the performance of the recirculating chiller refrigeration system. The correct choice of expansion valve will maximize the use o...
Ver detalles -
Professional introduction of dynamometer with motor cooling device
2397In the test of AC and DC motor and power tool, the test equipment such as dynamometer is often used. The dynamometer mainly tests the torque, speed and output power of the motor. The speed of the dynamometer usually Professional introduction of d...
Ver detalles -
How does the cooling and heating circulator equipment control the temperature of the jacket glass re
1704The cooling and heating circulator equipment is often equipped with a reaction kettle for temperature control, so how to connect and control the temperature? 1. Circular jacket inlet and outlet interface We mainly use flange interfaces for the in...
Ver detalles
工業冷水機製造商 LNEYA Taiwan