Explicación detallada de la atención a la depuración del sistema de refrigeración de circulación cerrada
The preparation of the closed circulation cooling system before commissioning is an important part of the debugging process, which may affect the progress of the whole debugging process. Generally, attention should be paid to the leakage detection of the closed circulation cooling system air piping system, and the leakage of the closed circulation cooling system. There are detailed regulations for the quantity, which are roughly divided into high, medium and low pressure systems. Under different pressures, the air leakage value per square meter per hour is different. The second is the visual inspection of the pipeline system. The main content of this work is to inspect the pipeline system to ensure that the various valves on the diffuser, branch pipe and main pipe are fully open to ensure that the pipeline system is in the all-pass state. Furthermore, the preparation of the closed loop cooling system commissioning equipment. Before commissioning, prepare the required test equipment including the equipment required for testing temperature, humidity, pressure, speed, and speed. The closed-loop cooling system is often prepared for different piping systems and their pre-installation work. Different, you should pay attention to this in actual work.
For the closed-circulation cooling system, when the pump and the main unit are both turned on, the end-to-end end is debugged, the valve for the end supply and return pipe that was originally turned off is turned on, and the water supply and return main pipe and the main circuit that are opened when the pipe is cleaned are turned off. On the bypass valve, see if the two-way valve is normal. If it is abnormal, check whether there is a problem with the closed circulating cooling system. Is there any electricity, or the coil of the valve has burned out? If the coil is burned without spare parts, the manual switch of the valve can be used. Forcibly open the two-way valve for commissioning.
In the actual operation of the closed circulation cooling system, the heating capacity of the closed circulation cooling system unit changes due to the difference in ambient temperature and the required temperature of the hot water supply in the refrigeration system. The heating capacity of the closed circulation cooling system unit decreases with the increase of the hot water outlet temperature and decreases with the decrease of the ambient temperature. The input power of the closed circulation cooling system unit under heating conditions increases with the increase of the outlet temperature of the hot water, and decreases with the decrease of the ambient temperature.
On the basis of the installation of the closed circulation cooling system, the corresponding closed circulation cooling system valve opening adjustment can be carried out, which is very helpful to improve the debugging speed and efficiency of the closed circulation cooling system and reduce the commissioning cost.
On the basis of this, the closed loop cooling system commissioning personnel continuously learn to continuously debug and make the closed circulation cooling system equipment achieve better running state.
Recomendaciones relacionadas
-
Ic test equipment manufacturer test project description
2227Los fabricantes de equipos de prueba de ic deben prestar atención al proceso de prueba al realizar las pruebas del proyecto. Los usuarios pueden hacer que el equipo de prueba de ic funcione de manera más eficiente a través de una comprensión detallada. El equipo de prueba de ic es responsable de la exclu...
Ver detalles -
What are the conditions for the decarboxylation reaction? How to control the temperature of heating?
2346The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group i...
Ver detalles -
Take You To Know The Performance Of LNEYA Industrial Freezer Accessories
1489Temperature Controller The temperature controller is used for control or protection of the unit. When the temperature reaches the set value, the switch automatically cuts off (or turns on) the circuit. In our products, temperature control is often...
Ver detalles -
Precautions for the use of chemical refrigeration and heating circulation systems
1896In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Ver detalles
工業冷水機製造商 LNEYA Taiwan