Low-temperature coolant circulation pump used with rotary evaporator
The chemical and pharmaceutical fields are the largest end consumer markets for cryogenic coolant circulation pumps. With the increasing demand for low-temperature coolant circulation pumps in this market, the application of cryogenic pumps in the chemical industry is becoming more mature. As a laboratory instrument, cryogenic coolant circulation pumps are indispensable to the laboratory field. It plays an important role in chemical, pharmaceutical and chemical research.
The low-temperature coolant circulation pump can directly cool test tubes, reaction flasks, etc. to carry out chemical reactions at low temperatures, and carry out low-temperature storage of chemicals and biological products. It can also be used in conjunction with rotary evaporators, vacuum freeze-drying boxes, circulating water-type multi-purpose vacuum pumps, etc.
One low temperature coolant circulation pump with two rotary evaporation laboratory cases Note points:
When in use, the actual temperature should not be lower than the minimum temperature. If water is used as the circulating solution, the water inlet pipe cannot be higher than 60 degrees Celsius, but when using absolute ethanol, the water inlet can not be higher than 10 degrees Celsius.
Lneya low-temperature coolant circulation pump adopts international brand compressor, which has small volume and high efficiency. Single compressor can achieve -152°C temperature control. The shell material is cold-rolled steel plate, and the circulating pump with pressure ≤6bar can be customized to make the liquid storage larger capacity according to the needs. Exclusive self-cascade supercooling refrigeration technology, in order to save water resources, can use ethylene glycol-water mixture for circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, extend the circulating water use time; -125 ° C ~-20 °C Wide temperature range; adjustment unit 0.1 degree. Ambient temperature monitoring function is provided to prevent damage to the system when the ambient temperature is too high.
Recomendaciones relacionadas
-
¿Cuál es la temperatura del circulador de refrigeración criogénica?
2019The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Ver detalles -
Sistema de control de temperatura de la máquina de recubrimiento por deposición de vapor-sistema de agua de refrigeración
2164El objetivo principal de la máquina de recubrimiento por deposición de vapor es llevar a cabo experimentos científicos e investigaciones sobre el proceso de formación de películas. Se compone de cámara de reacción de tubo de cuarzo, armario de horno de blindaje térmico, sistema de control eléctrico, vacío...
Ver detalles -
Detalles del sistema de control de la temperatura del reactor aislado
2025El sistema de control de temperatura del reactor aislado adopta el medio termoconductor para realizar el control dinámico de temperatura del enfriamiento y calentamiento del fluido, y para controlar el enfriamiento y calentamiento del medio termoconductor o del mate...
Ver detalles -
Consejos de marca del ultracongelador
1757Cuando se trata de congeladores de temperatura ultra baja, la mayoría de las personas se preocupan porque la temperatura ultra baja significa que la tecnología se vuelve más difícil. En comparación con otras plantas de refrigeración, las opciones de congelador de temperatura ultra baja...
Ver detalles