Influencia del aceite de congelación en el sistema de ensayo de motores de propulsión de vehículos de nueva energía
The hazard of the refrigerating oil in the new energy vehicle drive motor test system increases the condensation temperature and the condensing pressure; the condenser heat transfer deteriorates. Because the oil film produced by the oil entering the condenser has a thermal conductivity much smaller than that of the metal, the thermal resistance is increased and the heat transfer coefficient is reduced. The refrigeration oil in the new energy vehicle drive motor test system reduces the evaporation temperature and the evaporation pressure, and the compressor cooling capacity decreases, and the unit power consumption increases, making it difficult to cool down the cold. There are two reasons for this. On the one hand, it is consistent with the cause of the condenser; on the other hand, due to the accumulation of oil in the evaporator, the effective area of the evaporator is reduced.
The refrigeration oil in the new energy vehicle drive motor test system is prone to blockage, causing the system to work abnormally. This is mainly due to the high viscosity of the oil, which is easy to mix with dirt and mechanical impurities into a gel-like substance. When the gel-like substance accumulates in a pipe or valve with a small cross section, it is easy to cause blockage and cause refrigeration conditions. disorder. In order to avoid and reduce the entry of oil, the new energy vehicle drive motor test system, in addition to setting the oil separator with good performance and correctly grasping the fuel quantity of the compressor, the regular oil discharge work of the refrigeration equipment must be done during operation. In addition, you should also pay attention to the balance between the amount of oil added and released. If it is found that the amount of fuel added to the compressor is increased and the amount of oil released is reduced, the cause should be eliminated in time and the number of times of oil discharge should be increased to prevent excessive oil from entering the refrigeration system.
The impact of the refrigeration oil in the new energy vehicle drive motor test system is self-evident. It is recommended that the new energy vehicle drive motor test system adopt a fully enclosed circulation pipeline so that oil mist and refrigeration oil and other faults will not occur during operation.
Recomendaciones relacionadas
-
What is a laboratory glycol chiller What should I pay attention to
2368The laboratory glycol chiller is a common cooling equipment in the laboratory. It is generally used to achieve the temperature requirement of the cold source. What are the benefits? 1. Why choose a laboratory glycol chiller: The single-machine s...
Ver detalles -
How To Choose The Equipment For The Reactor?
1655The choice of equipment for the reactor needs to be measured by the following points: 1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 ton...
Ver detalles -
Motor test bench test and temperature system for vehicle components
2715All vehicle components must undergo rigorous testing, but safety programs must undergo more stringent durability and terminal testing. Many physical methods can be used to load the motor, but the small motor test bench is favored for its high spee...
Ver detalles -
Características y aplicaciones de las enfriadoras de glicol
2090El enfriador de glicol se aplica al proceso de enfriamiento de máquinas rectificadoras, máquinas herramienta CNC y varias máquinas herramienta de precisión, que pueden reducir eficazmente la deformación térmica de las máquinas herramienta, mejorar la precisión de mecanizado de las máquinas herramienta y...
Ver detalles
工業冷水機製造商 LNEYA Taiwan