El pequeño compresor de la cámara de pruebas ambientales debe prestar atención después del mantenimiento
En la cámara centrífuga de pruebas ambientales a pequeña escala, el dispositivo de recuperación de la succión es generalmente un sistema independiente y, si es necesario, la tubería conectada al condensador y al evaporador puede cerrarse para su mantenimiento por separado. Después de r...
After replacing the compressor in the small environmental test chamber, the pumping recovery device generally uses the automatic mode to open, stop and work during the operation of the unit. Therefore, the oil level of the oil separator of the piston compressor should be strictly monitored. Strictly monitor the level of the refrigerant in the recovery condenser. If the liquid level is not visible, the recovery condenser is not effective. Check whether the coolant line and the filter are blocked. If the non-condensable gas removed by the bleed valve contains more refrigerant gas, check if the float valve at the top of the recovery condenser is stuck.
If the venting valve that is automatically vented in the small environmental test chamber does not open the deflation when the specified pressure value is reached, the operation of the suction recovery device should be stopped and the exhaust valve should be overhauled. Frequent activation of the pumping recovery unit indicates that a large amount of air has leaked into the unit. Before the start of the refrigeration unit or during the start-up process, the manual operation of the suction recovery device is generally adopted. The time of each operation is limited by the decrease of the condensing pressure and the heat of the piston compressor motor casing. Generally, the continuous operation time is less than 30 minutes. If the small environmental test chamber is not used for a long time, it can be turned on for a short time to lubricate the compressor part. If the small environmental test chamber does not need to exclude non-condensable gases, the unit should also be operated for 15 to 20 minutes per day or several days.
The maintenance of the small environmental test box is also inevitable. It is recommended to make regular maintenance plans and carry out maintenance in a timely and effective manner.
Recomendaciones relacionadas
-
How to Debug the Expansion Valve of Low Temperature Freezer?
2281The effective operation of low temperature freezer is relevant to the needed refrigerating effect. It is crucial to correct expansion valve if better cooling effect is wanted. So, how to debug the expansion valve of low temperature freezer? During...
Ver detalles -
Instrucciones de funcionamiento del enfriador, un sistema de ciclos de control de temperatura de procesos de laboratorio
2174El medio de transferencia de calor del enfriador del sistema de circulación de control de temperatura de procesos de laboratorio utiliza aceite y agua. Utiliza calefacción eléctrica para calentar el medio de transferencia de calor (aceite de transferencia de calor o agua) que se ve obligado a circular en la tubería....
Ver detalles -
Arranque y parada del enfriador circulante de baja temperatura
2094Cuando se enciende el refrigerador de circulación de baja temperatura, puede encenderse automáticamente si se selecciona el arranque manual. El arranque automático necesita abrir la válvula de cierre de escape del compresor, arrancar la bomba de agua de refrigeraci...
Ver detalles -
LNEYA semiconductor refrigeration unit common fault description
2488If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary ...
Ver detalles
工業冷水機製造商 LNEYA Taiwan