Influence of refrigeration factors on high temperature enclosed explosion-proof industrial chillers
Check whether the high and low temperature enclosed explosion-proof industrial chiller is the cause of its own failure. The selection must be accurate. If the model is not in place, the required refrigeration effect will also not be achieved. It is recommended that the user purchase the required refrigeration capacity Such parameters are provided to the chiller manufacturer, and the professional selection is made to achieve the required refrigeration effect.
Envirnmental factor:
The high temperature enclosed explosion-proof industrial chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor, which indirectly affects the cooling effect. The refrigerant leaks or is insufficient, resulting in a decrease in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.
Factors affecting the cooling effect of equipment:
High-temperature enclosed explosion-proof industrial chiller condenser dust affects the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor refrigeration performance of high-temperature enclosed explosion-proof industrial chillers. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and begins to evaporate. After the compressor is compressed and the expansion valve is throttled, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the refrigeration effect.
Resuma
When the filter of the chiller is blocked, it will affect the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It is necessary to check regularly and clean the filter.
Recomendaciones relacionadas
-
LNEYA high and low temperature heating refrigerator maintenance instructions
2211High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high an...
Ver detalles -
Introduction to Heated Water Circulator System
2006The heated water circulation system (commonly known as hot treasure, backwater, heated water speeder, circulating water, heated water circulator, heated water preheater, preheating circulating system, etc.) is to solve the problem that hot water w...
Ver detalles -
The reason for the high pressure alarm of the TCU integrated temperature control unit
1878When the TCU integrated temperature control unit is used, it needs to be used according to the instructions in detail. Once problems are encountered, they need to be dealt with in time. Generally speaking, if we encounter a high pressure alarm fro...
Ver detalles -
Common Faults of Salt Spray Environmental Chambers
1993The enterprise users are often at a loss when dealing with common faults in the salt spray environmental chamber. For this reason, Wuxi LNEYA, a manufacturer of the salt spray environmental chamber, specially reorganized the related common fault t...
Ver detalles
工業冷水機製造商 LNEYA Taiwan