Precautions for Leakage Inspection of Glycol Chiller
The main points about checking leakage of glycol chiller
During the operation of the glycol chiller, it is critical that the refrigeration system does not leak.
In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy water or other methods. When the refrigeration cycle is in operation, the welds should not be cracked due to vibration, the pipes should not be blocked by debris during welding, and should not enter moisture due to improper operation. When the refrigeration cycle is working, the surface of the welded parts should be clean and clean. No oil stains.
The common leakage points of glycol chillers are evaporator leakage, refrigeration cycle connection leakage, refrigeration cycle valve leakage, compressor pipeline leakage, capillary vibration wear, four-way reversing valve leakage, etc. Common inspections Leakage methods are commonly used in the production and maintenance of refrigeration cycles: visual leak detection, pressure leak detection, instrument leak detection, vacuum leak detection, etc. The user can solve the leakage points one by one.
The fault of leak detection of glycol chiller is relatively common. Therefore, when choosing, it is recommended to choose a fully closed loop piping system and valve parts to choose branded accessories. The evaporator uses a high-power plate heat exchanger, which is small in size, high in efficiency, fast in cooling, safe and reliable, and is used for rapid liquid cooling. It is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.
Recomendaciones relacionadas
-
Common Failures of Salt Spray Environmental Chambers
2036When you encounter some common failures of salt spray environmental chambers, how to solve them? Wuxi Guanya Refrigeration Technology Co., Ltd. has brought the relevant fault tips as follows. Salt spray environmental chamber cannot spray Failure c...
Ver detalles -
What do the fault codes of air-cooled chillers mean
2194Generally, people will see 2 areas on the control panel of the device, namely PV area and SV area. The first one expresses the specific temperature, and the latter one is for setting the temperature. When a fault occurs, PV displays the number of...
Ver detalles -
¿Cuál es el refrigerante de los equipos de refrigeración por agua circulante?
1924Las diferentes industrias requieren diferentes temperaturas de refrigeración para los equipos de refrigeración por agua circulante, por lo que los refrigerantes seleccionados también son diferentes. A la hora de elegir un equipo de refrigeración por agua circulante, también es necesario...
Ver detalles -
Popularization of knowledge of Semiconductor Back-End Test high and low temperature control system
2077The Semiconductor Back-End Test high and low temperature control system is a necessary testing equipment for the metal, component, electronic and other material industries. It is used to test the degree of endurance of material structures or compo...
Ver detalles
工業冷水機製造商 LNEYA Taiwan