Introduction to mixed solution of glycol chilling systems (glycol chillers)
Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system.
Glycol is a class of organic compounds that belong to the alcohol family. When mixed with water and pumped through the pipes of a chilling system, glycol serves to slow the rate of freezing. It helps maintain temperature consistency in the application. Some glycol products also work to inhibit corrosion and bacterial growth within the pipes of the chilling system.
Glycol comes in two varieties that should never be mixed together: ethylene glycol and propylene glycol. Both types offer the same relative level of freeze protection. Both also help to guard against corrosion. Some grades of both types of glycol also help to prevent the growth of algae and bacteria within the chiller.
Ethylene glycol is a moderately toxic chemical that has a sweet taste and can be harmful if swallowed. For this reason, it should not be used in potable water or food processing systems when leakage is a possibility. Ethylene glycol has more widespread use due to its lower purchase price. Industrial applications like ice rinks and factories requiring large volumes of the coolant find this to be the most economical choice of glycol.
Mixing Water with Glycol in Your Industrial Refrigeration System
Although you should never mix glycol types there is something that should always be added: water. As mentioned, glycol must be mixed with water to function properly. The type and amount of water to use are key factors to consider.
Ratio of Water to Glycol to Use
Calculating the proper ratio of glycol to water in your chilling system depends on the coldest temperature that the glycol solution will reach during operation. If a chilling system is used indoors where there is no chance of freezing, the amount of glycol needed would be significantly less than required by a glycol chiller used outdoors where temperatures are prone to drop below freezing. Also, if an application requires a very low temperature to operate it should use a glycol mixture similar to that of an outdoor system. In a chilling system, this temperature is normally the saturated suction temperature in the evaporator, and normally this temperature is 10°F below the chiller set point temperature. Using the proper ratio of glycol and water in your chilling system is very important. Adding too much to your chiller system will cause it to become inefficient. However, not enough glycol could cause the system to freeze up, potentially bursting pipes or even rupturing the chiller evaporator.
To learn more about how a enfriador de glicol works, contact LNEYA: sales@lneya.com.
Recomendaciones relacionadas
-
Teoría del flujo de hielo, calidad del agua helada, flujo y presión de la máquina de agua helada
1665El ablandamiento del agua también es un problema importante en el proceso de utilización de enfriadoras. También es necesario observar continuamente el valor de pH del agua. El valor óptimo de pH debe ser igual a 7. Un valor de pH superior a 7 provocará una terrible corrosión...
Ver detalles -
Harm of dust to thermal oil temperature control system of reactor
1727Dust in daily work will also have a certain impact on the circuit board work of the thermal oil temperature control system of the reactor. Dust is an unevenly dispersed system composed of particles suspended in the air. It mainly comes from indu...
Ver detalles -
Efecto del instrumento evaporador para el experimento de baja temperatura en el sistema de refrigeración
2346De acuerdo con los diferentes modelos, la elección de los evaporadores para los instrumentos especiales de experimentación a baja temperatura también es diferente, como los instrumentos especiales de experimentación a baja temperatura tipo caja, que utilizan evaporador de serpentín de tanque de agua; ...
Ver detalles -
Temperature control mode of automatic control system of reaction kettle
1990The automatic control system of LNEYA reactor is the equipment used for temperature control of the reaction kettle. What are the temperature control methods of the automatic control system of the reactor? How are you controlling the temperature? T...
Ver detalles