High-low temperature control system with different configurations of high-pressure reactors
Different configurations of high pressure reactors, the quality of products brought by different manufacturers is not the same, but the points of attention are the same, you need to pay attention to it.
1. To be used at the designated location and follow the instructions for use. Check the test pressure, operating pressure, operating temperature and other conditions engraved on the main container, and use it within the allowable range of conditions.
2. The high-pressure reactor is a precision equipment. The sealing ring adopts the form of conical contact and sealing, and the main bolts are tightened to press them against each other to achieve the purpose of sealing. Special care must be taken for the sealing cone to avoid damage caused by various collisions.
When installing the cover, place the reactor body first, then put the cover in a fixed position and install it on the kettle body carefully. When tightening the main bolts, you must tighten them diagonally and symmetrically several times. Evenly, do not allow the kettle cover to tilt to one side to achieve a good sealing effect, and do not exceed the specified tightening torque to prevent the sealing surface from being squeezed or accelerated wear.
3. The pressure used by the pressure gauge of the autoclave should be used within 1/2 of the indicated pressure. And often compare the pressure gauge with the standard pressure gauge and make corrections. The pressure gauge for oxygen should not be mixed with pressure gauges for other gases. For safety valves and other safety devices, use equipment that has undergone regular inspections and meets the specified requirements.
When operating high-pressure reaction kettles with different high and low temperature integrated machine prices, it must be noted that the thermometer should be inserted into the reaction solution accurately. The interior of the autoclave and the gasket should be kept clean. When covering the disc flange cover, the bolts located on the diagonal line should be tightened in turn in pairs. When the measuring instrument is broken, it is mostly broken on the front and rear sides of its glass surface. Therefore, do not stand in these dangerous places during operation. When danger is expected, remove the glass and replace it with a new one.
Pay attention to the same points, but because the brands are different, the products brought are also different, and you need to buy them from regular manufacturers.
Recomendaciones relacionadas
-
Detailed Introduction of Air Cooled Chiller Equipment
2382LNEYA refrigeration has accumulated over 10 years of cooling supporting application experience. According to different application fields and service conditions, it has developed a variety of types of cooling chillers, including air cooled...
Ver detalles -
Tres fallos comunes de las enfriadoras de tornillo refrigeradas por aire
26641. Fallo de comunicación:El controlador del ordenador controla varios módulos mediante líneas de telecomunicación y la placa de interfaz total, por lo que la causa principal del fallo de comunicación es el mal contacto o la rotura de las líneas de comunicación, especialmente la interfaz oxida...
Ver detalles -
Pay attention to the installation of high and low temperature cooling circulator
2464The high and low temperature cooling circulators can only be operated better if they are installed correctly. If the installation is not in place during the installation process, the high and low temperature cooling circulators will have certain h...
Ver detalles -
Hable sobre los principales puntos de elección para el enfriador de agua circulante en el laboratorio
1854Circulating water cooler is also called chiller. It is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. Currently there are many kinds of chillers in the market. How to buy a suitable ch...
Ver detalles
工業冷水機製造商 LNEYA Taiwan