Low temperature industrial freezer fan coil wiring instructions
The electric two-way valve red line of the low-temperature industrial freezer is 220V hot wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected in series, green, brown, Yellow, corresponding to the thermostat connected to the fan coil high, medium and low gear, the black line is the two-way valve fire line to the thermostat “open” interface, the control line is 6 color 1.0 square national standard line.
It should be noted that the two-way valve is normally closed, the power is automatically turned off, the electric water circuit is turned on, and the air conditioner starts to cool; therefore, in the wiring process of the two-way valve, it is found that the terminal of the thermostat is “off”. No wiring is required. The low-temperature industrial refrigerator drive head is burned, and the general two-way valve will be automatically closed. The emergency measures can be forced to open the two-way valve through the small handle on the drive head to ensure the air cooling and heating.
When the low-temperature industrial refrigerator electric ball valve is wired, the red line is 220V fire line (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected in series, green, brown, Yellow, corresponding to the thermostat connected to the fan coil high, medium and low gear, black line for the two-way valve fire line to the thermostat “open” interface; Yan Hong line for the two-way valve to the thermostat “off” interface The control line is a national standard line of 7 colors and 1.0 square. It should be noted that this type of electric ball valve only needs to be energized once when the water circuit is turned on and off. When the action is completed, the power is automatically turned off. Unlike the above-mentioned low-temperature industrial refrigerator two-way valve, it is not necessary to energize the switch for a long time. Remove it and use a manual wrench to force the valve body to open or close.
The wiring of the electric two-way valve is not connected to the red wire 220V live wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil and the thermostat are connected in series, green, brown, yellow, respectively The thermostat is connected to the high, medium and low gears of the fan coil. The control line is a 5-color 1.0 square national standard line. The low temperature industrial freezer can only adjust the coil wind speed, and the temperature cannot control the opening and closing of the chilled water.
Different low temperature industrial refrigerators are somewhat different in these aspects, so we need to distinguish them one by one.
Recomendaciones relacionadas
-
Del 3 al 5 de noviembre, en el Centro Internacional de Exposiciones de Chongqing [CIPM], stand S3-07-2
1999LNEYA Exhibition Name: National Pharmaceutical Machinery Expo and China International Pharmaceutical Machinery Expo Exhibition time: November 3-05, 2020 Booth No.: s3-07-2 Exhibition address: Chongqing International Expo Center
Ver detalles -
Descripción de la selección de la bomba en la unidad de control de la temperatura del sistema saturado de vapor
2020The steaming system temperature control unit is one of the more used equipment in the pharmaceutical chemical industry. The performance of the LNEYA steaming system temperature control unit depends on the design of the whole system and the specifi...
Ver detalles -
Automotive antifreeze test test temperature control system
1994When it comes to car antifreeze, we all know that its main function is to prevent the coolant from freezing and cracking the radiator and freezing the engine cylinder block or cover when we stop in the cold winter. Make the cooling system in the ...
Ver detalles -
Cooling method for laboratory evaporative instruments in operation
1793Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When pu...
Ver detalles
工業冷水機製造商 LNEYA Taiwan