How To Choose The Equipment For The Reactor?
The choice of equipment for the reactor needs to be measured by the following points:
1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between.
2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 degrees, equipped with a cooling machine; there is also an oil cooling, suitable for high temperature resin, but the temperature should be greater than or equal to 200 degrees.
3. Material: Generally, there are SUS304 stainless steel, Q235 carbon steel, SUS316 stainless steel, etc.;
4. Stirring method: inclined blade type with inclined angle of 45-60 degrees; anchor type with scraping edge scraping; dispersing disc type with 1000/1500/2800 rpm for shearing (for paint or powder, Hot melt adhesive (rubber); and ribbon type for high viscosity with dispersing disc (for hot melt adhesive)
5. Sealing form: generally has mechanical seal, packing seal, double sealing surface, single sealing surface;
6. Structural aspects: generally have outer half tube type (more than or equal to 2 tons); outer jacket type (more than 3 tons); inner coil; no jacket (no heating); inner coil type (suitable for small viscosity, Small fluidity)).
7. The structure of the kettle body: determined according to size, material and thickness;
Wuxi Guanya LNEYA refrigeration heating temperature control system is the first choice for the reactor equipment, ultra-high temperature cooling technology, can directly cool down from 300 degrees high temperature. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
Recomendaciones relacionadas
-
¿Cómo conectar a tierra el conductor de prueba de la batería del vehículo eléctrico?
2000La prueba de la batería del vehículo eléctrico está en el estado de funcionamiento, y es necesario entender el funcionamiento de los accesorios, y la unidad y otros accesorios están en funcionamiento. Si la prueba de la batería del vehículo eléctrico no está aislado entre la A...
Ver detalles -
Effect Of Humidity On Laboratory Chillers
1929The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance...
Ver detalles -
Multi-stage refrigeration small temperature control compressor description
2077The function of the compressor in the multi-stage refrigeration small temperature control station system is to draw the refrigerant vapor of the evaporator and increase its temperature and pressure, which is discharged into the condenser. In the c...
Ver detalles -
New product recommendation-small desktop circulating chiller FL-800N
2229In recent years, with the rapid development of the pharmaceutical industry, the pharmaceutical equipment industry has also developed rapidly. To this end, Lneya launched the small desktop circulating chiller FL-800N, which is welcomed by the marke...
Ver detalles
工業冷水機製造商 LNEYA Taiwan











