TCU temperature control model selection and technical parameter description
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
Unidad de control de temperatura temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.
In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Recomendaciones relacionadas
-
16. – 18. June 2020 | The Automotive Testing Expo Europe-LNEYA
346The Automotive Testing Expo Europe is a trade fair for automotive test, evaluation and quality engineering. It is one of the most important event of its kind in Europe. The fair widtmet the latest technologies and services to improve quality, safe...
Ver detalles -
Pequeño golpe para tratar el bloqueo por hielo de los enfriadores de circulación de líquido de alta y baja temperatura
1618En el funcionamiento de las enfriadoras por circulación de líquido de alta y baja temperatura, el atasco de hielo es un fallo relativamente común. Basándonos en la experiencia de los fabricantes pertinentes, hemos recopilado especialmente consejos relevantes para solucionar los atascos de hielo. En la tubería...
Ver detalles -
How to reduce the condensing pressure of the heating circulator unit?
2194During the operation of the heating circulator unit, the temperature change inside the equipment will cause the condensing pressure to change. Especially in summer when the condensing pressure is too high, the power consumption of the compressor w...
Ver detalles -
Circulador De Baja Temperatura De Wuxi Guanya Tiene Más De 10 Años De Exploración E Innovación, Precipitati
2117Wuxi Guanya Refrigeration technology co., ltd es un fabricante profesional de equipos de refrigeración en China. Es una empresa orientada a la tecnología de producción que integra I+D, producción, ventas y postventa. Se especializa en la produ...
Ver detalles
工業冷水機製造商 LNEYA Taiwan