What should be paid attention to when placing the thermostat system?
There are certain differences in the size and performance of the high and low temperature thermostat systems produced by different manufacturers. The user needs to pay attention to how it is placed when placing it after purchase, otherwise it will be detrimental to the operation of the high and low temperature thermostat system.
The location where the high and low temperature thermostat system is installed should consider the heat dissipation efficiency and whether it is easy to check and maintain. The floor where the equipment is placed must be flat and have sufficient strength (3.4N/m2 or higher). Choose a place where dust and vibration are less affected s position.
The high and low temperature thermostat system should be installed in a dry room, and there should be a power supply and a sewer nearby. The equipment should be installed in a place with little dust, and the wind condition will cause the refrigerant (fluorohydrocarbon) to leak from the equipment. There will be no hypoxia.
Good ventilation should be maintained around the installation of the high and low temperature thermostat system. During operation, the equipment will radiate heat. If it is an air-cooled thermal shock, it will directly emit heat through the condensing wind. When the room is small and poorly ventilated, the indoor temperature will rise rapidly, causing the machine to stop running and alarm . Secondly, the installation should be far away from flammable or explosive materials or other materials that may generate high heat.
When placing it, please be careful not to let sunlight directly shine on the equipment. When the equipment is used beyond this range, the safety device will start or the equipment will stop running. In order to obtain stable performance of the high and low temperature thermostat system, the installation room should be air-conditioned to keep the indoor temperature between 10°C and 30°C.
The atmospheric environment of the installation site of the high and low temperature thermostat system is consistent with the general indoor air-conditioned atmospheric environment. If there are organic solvents, plasticizers, acids, alkalis or other chemicals in the air, the parts or coatings of the equipment will be corroded and damaged.
The above content is the precautions when placing the high and low temperature thermostat system, which requires the operator to take it seriously and read the instruction manual in detail.
Recomendaciones relacionadas
-
Precauciones de uso de la unidad de refrigeración por agua
1907Cautions To Use The Water Cooling Unit Manufacturers now use recycled water to save costs. However, many manufacturers put circulating water of the whole plant in one water network, which will lead to the problems that the temperature of circulat...
Ver detalles -
The Main Fuction of Low Temp Chillers
2025In the domestic industrial market, the low temp chiller is a very important production auxiliary equipment, which can provide suitable working environment for different industrial production. Condenser is one of the key parts of the low temp chill...
Ver detalles -
How to Debug the Expansion Valve of Low Temperature Freezer?
2281The effective operation of low temperature freezer is relevant to the needed refrigerating effect. It is crucial to correct expansion valve if better cooling effect is wanted. So, how to debug the expansion valve of low temperature freezer? During...
Ver detalles -
¿Sabes cómo ahorrar electricidad en el congelador a baja temperatura?
1991The name of low temp freezer should be known to all, that is, the temperature inside the cabinet will be very low, so since the temperature is low, the relative power consumption is more. So under such circumstances, how can we save electricity? A...
Ver detalles
工業冷水機製造商 LNEYA Taiwan